24
ENGLISH
“Condominium” mode
After the power is supplied to the electronic card the first start command determines an opening cycle. At the end of the two work times, the gate
stops. The pause period starts
(blinker off). At the end of the pause period the gate closes automatically. The operating cycle is complete only when
the closing motion has ended. If a start command is supplied while the gate opens, the command will have no effect. If a start command is supplied
while the gate closes, the gate will stop and reverse its motion after approx. 1.5 sec. If a start command is supplied during the pause period, the period
will be reset and the automatic closure will start later.
Important :
If the gate opening is controlled by a clock the “condominium” mode must be enabled.
Note :
At the beginning of each opening cycle the electric lock operates a split of second ( 0,8 sec ) at the same time as the wing (M2) starts. This
condition is enabled only if the dip switch 1 = OFF.
In any operation mode, the safety devices causes the following effects :
Stop :
If the stop command is enabled no cycles can start and the start command will have no effect. If a stop command is supplied during motion,
the gate will immediately stop e interrupt its operating cycle. This condition will continue until the stop command is on. A start command
following a stop command always determines an opening cycle. A stop command supplied during the pause period interrupts the operating
cycle. A start command subsequently supplied will start a closure cycle.
Photo-cell :
This device has effect only during the closure phase or in the pause period. If an obstacle covers the photo-cell during the closure
phase , the gate stops and reverses its motion after approx. 1,5 sec. If an obstacle covers the photo-cell during the pause period this last
one is reset and the automatic closure is therefore delayed.
Photostop :
If an obstacle covers the photo-cell during the gate’s motion (opening or closure), or during the period preceding the operating cycle’s
start, then the gate is temporarily stopped, until the obstacle is not removed. The blinker will light with a fixed light to signal the irregular
condition. When the obstacle is removed and the photocell is freed, an opening cycle will start. This does not apply when a start
command determines the closing phase in step-by-step mode at the end of an opening cycle. If an obstacle covers the photostop during
the pause period this last one is reset and the automatic closure is therefore delayed
Pedestrian start:
The pedestrian start command operates in the same way as the other start command, but in this case only the wing fitted with the
electric lock (M2) will be opened or closed. The pedestrian start command has no effect during a start cycle and up to the end of
the closing phase (closed gate). During a pedestrian start cycle the start command is active only in the closing phase.