background image

Snap-on Valve Controller

Installation Instructions

1

Locate the main incoming water supply valve. Note whether the valve is a 

¼

 turn ball valve or if it is a multi-turn 

gate valve having a round handle. Manually turn the valve to its off position and turn on the closest faucet to 

make sure the flow of water completely stops. 

Note:

 

If the valve is difficult to turn, requires a tool to operate, or is not completely shutting off the flow of water, 

we strongly recommend calling a plumber to have the valve replaced.

2

Place the correct LeakSmart valve handle adapter on the snap valve controller drive shaft.

Note: 

Make sure spring clip engages the notch in the shaft. This can be done by pushing up or down on the 

adapter with slight pressure.

Push in spring clip while

slipping adapter on to shaft

Ball Valve

Gate Valve

Item# 8852000

Ball Valve

Gate Valve

Push in spring clip while

slipping adapter on to shaft

page 1

CAUTION:

• The LeakSmart Snap Valve Controller is designed to be installed on an existing main water shutoff valve. 
• To avoid any injury, never place your fingers near the snap valve controller while it is operating. 
• This device is 

NOT

 to be installed on a valve supplying a fire suppression system or fire sprinkler water line.

• Indoor use only

Gate valves can be 

identified if having

flat sides.

If your shut off valve 

has a round body, it is 

considered a globe 

valve, and should 

NOT

 

be used with the snap 

valve controller. There 

is risk of damaging the 

rubber seals. 

Summary of Contents for 8852000

Page 1: ...ges the notch in the shaft This can be done by pushing up or down on the adapter with slight pressure Push in spring clip while slipping adapter on to shaft Ball Valve Gate Valve Item 8852000 Ball Valve Gate Valve Push in spring clip while slipping adapter on to shaft page 1 CAUTION The LeakSmart Snap Valve Controller is designed to be installed on an existing main water shutoff valve To avoid any...

Page 2: ...tall the snap valve controller over valve aligning the square valve stem with the adapter handle Insert the U bracket keeping clearance so fine adjustments can be made For fine adjustments see step 5 Note If the square does not align use the original valve handle to rotate the stem a 1 8th turn at a time going towards the opening position until the adapter fits onto the square stem see image 2 Ima...

Page 3: ...dicated in image below is in reference to the flat bottom of the snap valve controller and supply line Once level and having tool adapter engaged over center of valve stem see note below push the U bracket the rest of the way in Then continue to hand tighten the handle crank until firmly clamped to the supply pipe CAUTION Do not excessivley overtighten Push handle back down when finished Keep squa...

Page 4: ...o the LeakSmart hub follow the in app paring instructions when tapping on Add Devices 6 Remove the battery compartment door and install the four 4 AA batteries in the battery holder Note The snap valve controller will not go into calibration mode Step 8 when running on battery power alone The AC power cord must be plugged in see step 7 Batteries LeakSmart Bedford Heights Ohio 44146 Designed in U S...