LEAKSHOOTER LKS1000 User Manual Download Page 2

 

 

W

HAT IS 

LEAK

SHOOTER

 

LKS

1000 ? 

 

LEAK

SHOOTER

 

LKS

1000

 IS A PORTABLE DEVICE WHICH GIVES YOU THE POSSIBILITY TO HEAR

,

 MEASURE

,

 VIEW AND STORE 

THE LEAKS

M

AIN 

F

UNCTIONS

-

 

D

ETECTION AND LOCALIZATION OF ULTRASOUND THANKS TO AUTOMATIC DYNAMIC TARGET

 

-

 

L

ISTEN TO THE ULTRASOUND WITH HETERODYNE TECHNIQUE 

(40

K

H

>

 

2.5

K

H

Z

-

 

M

EASURE AND DISPLAY OF 

RMS

  IN REAL TIME AND 

MAX

 

RMS

 ON A COLORED BARGRAPH

 

-

 

V

ISUALIZATION ON SCREEN OF ULTRASONIC WAVES PRESENCE 

(

EXACT LOCATION OF LEAK

-

 

N

UMBERED AND STAMPED RECORDING OF THE BITMAP WITH ALL ULTRASONIC INFORMATION

 

 

LEAK

SHOOTER

 

LKS

1000,

 THE FIRST ULTRASONIC DETECTION CAMERA DEDICATED TO LEAKS

,

 THOUGHT AND DEVELOPED 

BY 

LEAK

SHOOTER,

 A DIVISION OF 

SYNERGYS

 

TECHNOLOGIES

 

(FRANCE). 

 

 

 

All manuals and user guides at all-guides.com

Summary of Contents for LKS1000

Page 1: ...ersion 1 2 19 02 2013 www leakshooters com info leakshooters com LEAKSHOOTER LKS1000 USER MANUAL VERSION 1 2 ULTRASONIC DETECTION CAMERA PATENT PENDING All manuals and user guides at all guides com a...

Page 2: ...HETERODYNE TECHNIQUE 40KHZ 2 5KHZ MEASURE AND DISPLAY OF RMS IN REAL TIME AND MAX RMS ON A COLORED BARGRAPH VISUALIZATION ON SCREEN OF ULTRASONIC WAVES PRESENCE EXACT LOCATION OF LEAK NUMBERED AND ST...

Page 3: ...USING VERY SENSITIVE ULTRASONIC DETECTOR AND HETERODYNE TECHNIQUE OFTEN CENTERED AROUND 40 KHZ IT IS POSSIBLE TO FIND AND LISTEN TO THE LEAK EASILY WHY ULTRASONIC WAVES ARE EASY TO FIND WITH AN ULTRAS...

Page 4: ...0 KEYBOARD o ON OFF o INCREASE OF HEADSET VOLUME o DECREASE OF MEASUREMENT GAIN ESCAPE o DECREASE OF HEADSET VOLUME o PHOTO CAPTURE o MENU SETTINGS VALIDATION o INCREASE OF MEASUREMENT GAIN All manual...

Page 5: ...NUMBER AND TIMESTAMP STORED IN MEMORY o CAMERA REAL TIME VIEW o DYNAMIC TARGET SHOWING LEAK ZONE o REAL TIME RMS AND MAX RMS VALUES o RMS MEASUREMENT VALUE o POWER o USB PC o JACK FOR AUDIO HEADPHONE...

Page 6: ...KS 1000 o HEADSET WITH JACK CABLE SNR 31 LKS EAR o UNIVERSAL BATTERY CHARGER LKS POWER o USB CABLE FOR PC LKS USB o USER MANUAL ON CD LKS MANUAL o SOFTWARE FOR PC LKS PC VIEWER FLEXIBLE 400 MM SENSOR...

Page 7: ...HARGING INSTRUCTIONS LEAKSHOOTER LKS1000 AUTOMATICALLY SWITCH OFF WHEN VOLTAGE BATTERY IS TOO LOW BATTERY EMPTY TO HAVE THE BEST CHARGING TIME THE BEST CAPACITY YOU SHOULD CHARGE BATTERIES ONLY WHEN M...

Page 8: ...IETLY AND CONSCIENTIOUSLY AUTO GAIN MODE DEFAULT MODE USED AFTER LKS1000 POWER ON THIS MODE IS USED FOR CLASSICAL APPLICATION SMALL AND MEDIUM LEAKS WHERE THE GAIN WILL BE AUTOMATICALLY ADJUSTED FACE...

Page 9: ...IF YOU ARE FACE TO THE LEAK TARGET WILL BE RED WITH A CROSS INSIDE DO NOT FORGET TO READJUST THE GAIN TO THE MAX OR IN AUTO WHEN YOU CHANGE YOUR LEAKS RESEARCH LEAK DETECTION SEARCH PROCEDURE WITH FL...

Page 10: ...YOU ARE FACE TO THE LEAK LOCATION SEE BELOW CASE N 3 CASE N 3 FACE TO A SMALL LEAK REAL TIME RMS MAX AND IN GREEN COLOR NO NOISE IN THE HEADPHONES REAL TIME RMS MAX 3DB AND IN YELLOW COLOR YELLOW TARG...

Page 11: ...OT TO LISTEN DURING A LONG TIME WITH A HIGH LEVEL VOLUME ON YOUR EARS SYNERGYS TECHNOLOGIES WILL NEVER BE RESPONSIBLE OF AN INAPPROPRIATE SETTING OF THE HEADPHONES VOLUME WHICH CAN CAUSE ON A LONG TER...

Page 12: ...Z THE FREQUENCY MIXER ALLOWS TO HAVE A BETTER FINEST SIGNAL RESULT EFFICIENCY ON HEADPHONES LISTENING BECAUSE OF THE CAPABILITY TO ADAPT MIXING FREQUENCY FROM 34 TO 46 KHZ FOR STANDARD LEAK APPLICATIO...

Page 13: ...MAIN USE DATE TIME USB LINK TO PREPARE USB CONNECTION WITH PC AUTO POWER OFF DELAY TIME DELAY TO SWITCH OFF THE DEVICE AUTOMATICALLY LANGUAGE FRENCH ENGLISH DEUTSCH TO NAVIGATE THROUGH THE MENU USE UP...

Page 14: ...R SET BY USER USING THE JOYSTICK BETWEEN 000 AND 999 AND TIME STAMPED FIG C THEN CLICK ON BUTTON PICTURE WILL BE FINALLY STORED IN MEMORY WITH CHOSEN NUMBER FIG A FIG B FIG C DELETE A PHOTO TO DELETE...

Reviews: