background image

 

www.leahualight.com 

 

  7 

 

0-127  No movement 

128-200 Reset (last above 3 seconds) 
201-255 No movement 

13 

 

Lamp control   

0-9 

No movement   

10-100  Off(last above 3 seconds)   

101-255 On (last above 3 seconds) 

 

 
 
 
 
5    DIFFICULTY RESOLUTION

 

The  following  is  a  list  of  problems  and  resolution,  and  other 

malfunction  preparing  work  should  be  professionally  qualified  staff to 

deal with.   

1. Bulb not working   

a)

 

Check whether approaching the service life of light bulbs, then 

change it 

b)

 

Check whether bulbs circuitry leak, loss or connect poorly 

2. Beam appears bleak 

a)

 

The bulbs maybe  approach the service life, then change it, or 

the optical components are unclean. 

b)

 

Bulbs have accumulation of dust, so the bulbs and other parts 

inside  the  lamp  should  be  cleaned  and  maintained  in  regular 

period. 

Summary of Contents for LH-N006

Page 1: ...rial Zone Zhu Gang Road Hongxing Shijing Town Baiyun District Guangzhou China Tel 86 020 66292177 Fax 86 020 66292177 LH N006 Roller Beam 5R User Manual This manual contains important information Plea...

Page 2: ...nd humid environment before using the lights must ensure the good grounding can not install charging and remove any parts the installation of lamps must be fixed screw fasteners with additional securi...

Page 3: ...en output 20000LM 10meter Color Temperature 8000K Prism 8 Prism rotation Gobo wheel 14 gobos white Color wheel 13 colors white rainbow effect DMX Channel 13CH Control DMX512 Sound Master Slave Auto Fo...

Page 4: ...Color Gobo Prism Frost Strobe 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 Display Language Screen saver Screen rotion English Chinese Mode1 mode2 off Off on Adva Pan invert Tilt i...

Page 5: ...degree 3 Barrel rotation 0 127 Barrel rotation angle 0 400 degree 128 191 Forwards Barrel rotation from fast to slow 192 255 Backwards Barrel rotation from slow to fast 4 Color Wheel 0 9 white 10 19 C...

Page 6: ...Rot gobo 2 15 19 Rot gobo 3 20 24 Rot gobo 4 25 29 Rot gobo 5 30 34 Rot gobo 6 35 39 Rot gobo 7 40 44 Rot gobo 8 45 49 Rot gobo 9 50 54 Rot gobo 10 55 59 Rot gobo 11 60 64 Rot gobo 12 65 69 Rot gobo 1...

Page 7: ...shake 250255 Rot Gobo 14 shake 6 Shutter strobe 0 3 Shutter closed 4 103 Strobe slow to fast 104 107 Shutter open 108 207 Pulse strobe slow to fast 208 212 Shutter open 213 225 Random slow strobe 226...

Page 8: ...function preparing work should be professionally qualified staff to deal with 1 Bulb not working a Check whether approaching the service life of light bulbs then change it b Check whether bulbs circui...

Page 9: ...ommunication control circuit b The corresponding channel button of controller is open or not c Check whether the fuse on power supply input jack is broken off 6 AFTER SERVICE 1 Our company offer techn...

Page 10: ...the manufacturer 2 The following will be the implementation of paid service 1 Without the effective warranty card 2 There s blank alter and no point of sale name 3 Fail caused by unresistance 4 Fail c...