M a nua l  

random  password)  can  not  more  than  20  digits,else  system 

will indicate "it is wrong" 

 

Selectable functions 

Read cabinet lock information 

Use PDA  can collect latest turn  on records

200  pcs

,include 

turn  on  time,turn  on  password,and  status

after  collected  these 

information,you can read it on software or PDA

 

 

Work enviroment 

Working temperature

: -25

℃~

+65

 

Working humidity

:5%

95%RH 

 

Parameter   

Use time

More than

 

100 thousand

 

Electronic control part

 

A.Power supply

4 pcs AAA alkaline batteries

 

B.Static current

When indicate LED turn off,static current 

5u

C.Transient current(Turn on lock)

≤250mA

 

D.Work current for operating keypad

≤20mA

 

E.Anti-static current:Anti air discharge 15KV

contact discharge 8KV 

4. Service after sale 

 

Service after sale 

1.

 

Quality guaranty   

         

   

Our product have got a 100% test before leave factory, correspond 

with

 

ISO  quality  certification  system,  provide  technical  information 

(including  install  and  usage  specification,  certificate  of  quality,  warranty 

Summary of Contents for DH 112Y

Page 1: ...User manual...

Page 2: ...RRO INDICADOR N O DEFINIDO Picture Lock cylinder structure 2 Accessories 3 2 INSTALLAND USE 4 3 OPERATION 5 Change password 8 Turn on lock 8 Turn off lock 8 Slectable functions 8 Work enviroment 9 Par...

Page 3: ...LEAF TECHNOLOGIES DH 112Y 2 Manual 1 Lock size and accessories PICTURE LOCK PANEL STRUCTURE PICTURE LOCK CYLINDER STRUCTURE...

Page 4: ...supply Automatic lock catch Achieve open the door automatic optional Strong elasticity and endurance General lock strike Close door when the bolt is lock Normal accessory Design on the humanized scr...

Page 5: ...LEAF TECHNOLOGIES DH 112Y 4 Manual 2 INSTALL AND USE...

Page 6: ...ter code set successfully Remark After used the master code to turn on lock the user code will return back to the default code 0 Please change the master code in time and keeping properly for emergenc...

Page 7: ...e master code or the frame hopping to open user code will return to default code 1111 Turn off lock Private type Push the cabinet door to the close situation then can turn off lock Public type When ca...

Page 8: ...can turn on lock about 100 times 5 Password digits User code and Master code 4 10 digits Frame hopping is 10 digits 6 Restore password 1 When users forget password input master code to turn on and the...

Page 9: ...indicate the cabinet already occupied and it is in using This function only suitable for Public mode Turn on state indicate function 8 Master code Turn off state indicate function 9 Master cod 11 Fra...

Page 10: ...5 95 RH Parameter Use time More than 100 thousand Electronic control part A Power supply 4 pcs AAA alkaline batteries B Static current When indicate LED turn off static current 5uA C Transient curren...

Page 11: ...ring three guarantees period if get repaired twice and still cant work you can provide the record on the guarantee card and the certification then we will change the same product for free or returned...

Page 12: ...ding displacement is unready 1 Use the external power supply to open change the battery immediately after open 2 reset the winding displacement or change it Press the key and have no reaction yellow l...

Reviews: