Leadshine Technology MA860 User Manual Download Page 8

                                 

MA860 Microstepping Driver Manual V1.0

 

Tel: +086 0755-26434369                                11                                  Web Site: www.leadshine.com 

10. Sequence Chart of Control Signals 

In  order  to  avoid  some  fault  operations  and  deviations,  PUL,  DIR  and  ENA  should  abide  by  some 
rules, shown as following diagram: 

 

Figure 11: Sequence chart of control signals 

Remark: 

a)

 

t1:  ENA  must  be  ahead  of  DIR  by  at  least  5

µ

s.  Usually,  ENA+  and  ENA-  are  NC  (not 

connected). See 

Connector P1 Configurations

 for more information. 

b)

 

t2: DIR must be ahead of PUL effective edge by 5

µ

s to ensure correct direction; 

c)

 

t3: Pulse width not less than 1.5

µ

s; 

d)

 

t4: Low level width not less than 1.5

µ

s. 

11. Protection Functions 

To improve reliability, the driver incorporates some built-in protections features. 

Short-voltage and Over-voltage protection   

When  power  supply  voltage  is  lower  than  13VAC  or  +18VDC,  short-voltage  protection  will  be 
activated  and  power  indicator  LED  will  turn  off.  When  power  supply  voltage  exceeds  67VAC  or 
+94VDC, over-voltage protection will be activated and Alarm indicator LED will turn on.   

Over-current Protection 

Protection will be activated when continuous current reaches to 16A. 

                                 

MA860 Microstepping Driver Manual V1.0

 

Tel: +086 0755-26434369                                12                                  Web Site: www.leadshine.com 

Short Circuit Protection 

Protection  will  be  activated  in  case  of  short  circuit  between  motor  coils  or  between  motor  coil  and 
ground. 

12. Frequently Asked Questions 

In the event that your driver doesn

t operate properly, the first step is to identify whether the problem 

is electrical or mechanical in nature. The next step is to isolate the system component that is causing 
the problem. As part of this process you may have to disconnect the individual components that make 
up  your  system  and  verify  that  they  operate independently.  It is  important to  document  each step  in 
the  troubleshooting  process.  You  may  need  this  documentation  to  refer  back  to  at  a  later  date,  and 
these  details  will  greatly  assist  our  Technical  Support  staff  in  determining  the  problem  should  you 
need assistance. 

Many of the problems that affect motion control systems can be traced to electrical noise, controller 
software errors, or mistake in wiring. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for MA860

Page 1: ...otice to any products herein to improve reliability function or design Leadshine does not assume any liability arising out of the application or use of any product or circuit described herein neither does it convey any license under its patent rights of others Leadshine s general policy does not recommend the use of its products in life support or aircraft applications wherein a failure or malfunc...

Page 2: ...ull Coil Configurations 6 Connections to 8 lead Motors 6 Series Connections 6 Parallel Connections 7 6 Power Supply Selection 7 Regulated or Unregulated Power Supply 7 Multiple Drivers 7 Selecting Supply Voltage 8 7 Selecting Microstep Resolution and Driver Output Current 8 Microstep Resolution Selection 8 Current Settings 9 Dynamic current setting 9 Contents II Standstill current setting 9 8 Wiri...

Page 3: ...upport PUL DIR and CW CCW modes l Short voltage over voltage over current and short cicuit protection Applications Suitable for a wide range of stepping motors from NEMA size 17 to 43 It can be used in various kinds of machines such as X Y tables labeling machines laser cutters engraving machines pick place devices and so on Particularly adapt to the applications desired with low noise low heating...

Page 4: ...ed to motor driver wiring match Exchanging the connection of two wires for a coil to the driver will reverse motion direction ENA ENA Enable signal This signal is used for enabling disabling the driver High level NPN control signal PNP and Differential control signals are on the contrary namely Low level for enabling for enabling the driver and low level for disabling the driver Usually left UNCON...

Page 5: ... at higher speeds This configuration is also referred to as half chopper In MA860 Microstepping Driver Manual V1 0 Tel 086 0755 26434369 6 Web Site www leadshine com setting the driver output current multiply the specified per phase or unipolar current rating by 1 4 to determine the peak output current Figure 6 6 lead motor half coil higher speed connections Full Coil Configurations The full coil ...

Page 6: ...he driver draws current from the power supply capacitor of the unregulated supply only during the ON duration of the PWM cycle but not during the OFF duration Therefore the average current withdrawn from power supply is considerably less than motor current For example two 3A motors can be well supplied by one power supply of 4A rating Multiple Drivers It is recommended to have multiple drivers to ...

Page 7: ...igh speed condition Standstill current setting SW4 is used for this purpose OFF meaning that the standstill current is set to be half of the selected MA860 Microstepping Driver Manual V1 0 Tel 086 0755 26434369 10 Web Site www leadshine com dynamic current and ON meaning that standstill current is set to be the same as the selected dynamic current The current automatically reduced to 60 of the sel...

Page 8: ...n will be activated and Alarm indicator LED will turn on Over current Protection Protection will be activated when continuous current reaches to 16A MA860 Microstepping Driver Manual V1 0 Tel 086 0755 26434369 12 Web Site www leadshine com Short Circuit Protection Protection will be activated in case of short circuit between motor coils or between motor coil and ground 12 Frequently Asked Question...

Page 9: ...sons of improper or inadequate handlings by customer improper or inadequate customer wirings unauthorized modification or misuse or operation beyond the electrical specifications of the product and or operation beyond environmental specifications for the product Obtaining warranty service To obtain warranty service a returned material authorization number RMA must be obtained from customer service...