CS-D1008E Closed Loop Stepper Drive User Manual
Page | 10
3) Usually keep factory settings
output
current
fluctuates
from 3-6A
following
the load)
A
0
75
10
B
0
100
5
C
16
25
25
D
16
50
15
E
16
75
10
F
16
100
5
Note: “factory” means the factory switch setting, “default” means the parameters can be set by Leadshine software.
6.2 S2 - DIP Switch Configurations
The 8-bit is located on the side (DIP switch S2 in Figure 2) and used to configure settings of micro step resolution,
output current, and motor standstill current as shown below.
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
Figure 6: DIP switches
6.2.1 Micro Step (SW1-SW4)
Each CS-D1008E has 15 microstep settings which can be configured through DIP switches SW1, SW2, SW3 and SW4.
See the following table for detail.
Micro step
Pulses/Rev. (for 1.8°motor)
SW1
SW2
SW3
SW4
8 (default)
1600
on
on
on
on
4
800
off
on
on
on
8 (factory)
1600
on
off
on
on
16
3200
off
off
on
on
32
6400
on
on
off
on
64
12800
off
on
off
on
128
25600
on
off
off
on
256
51200
off
off
off
on
5
1000
on
on
on
off
10
2000
off
on
on
off
20
4000
on
off
on
off
25
5000
off
off
on
off
40
8000
on
on
off
off
50
10000
off
on
off
off
INP or BRK
Pulse mode
Rotation direction
Microstep