4.2 Pairing the seismic sensor
To be recognised by a control box, the sensors must be paired to it. Initially the sensors are paired with
the control box they are delivered with in the factory.
However, each sensor can be used on any
LEADER Search
control box.
If you need to pair a sensor to another control box, follow the sequence described below:
1.
Turn off the control box.
2.
With the sensor powered off, press the push button for 15 seconds and then release it. The green
LED will flash very quickly and then go out at this stage the sensor is no longer paired to any control
box.
3.
Turn on the sensor to be paired. The sensor's LED flashes very quickly again. If the LED
on the sensor to be paired does not flash quickly, repeat step 2.
4.
Turn on the control box. The sensor will then carry out the pairing sequence for a few seconds
and then switch off automatically.
5.
Switch the sensor back on. it is now recognised by the control box and its bar-chart format signal
appears on the screen.
A selector in the sensor battery compartment can be used to select the sensor number
(n°1, n°2 or n°3).
The sensor number is memorised by the sensor during the pairing sequence. To make the sensor memorise
a new number, it should first be unpaired, the switch must be placed on the required sensor number,
and then the pairing sequence carried out.
Once paired, the sensor keeps the number assigned to it, even if the selector is mistakenly positioned
on another number.