126
13. STATUS DISPLAY
STATUS → F•2 DATA DUMP →F•1 MODE: RUN / STOP
No.
Item
Description
can select the data display format by pressing F•2 DISPLAY.
Reference 13.3.3, “Selecting the Display Format”
13.3.2
Selecting the Display Mode
To set the data dump display mode, follow the procedure below.
Procedure
Settings
RUN:
The input signal data is automatically updated and displayed.
STOP:
The input signal data is retained and displayed.
13.3.3
Selecting the Display Format
To select the data dump display format, follow the procedure below.
Procedure
STATUS → F•2 DATA DUMP →F•2 DISPLAY: SERIAL / COMPO / BINARY / STREAM1 /
STREAM2 / STREAM12
Settings
SERIAL:
The data is converted from parallel to serial data and displayed.
This option cannot be selected when the input signal is 3G-B-DL.
COMPO:
The data is converted from parallel to serial data, split into Y, Cb, and Cr or G,
B, and R, and then displayed.
This option cannot be selected when the input signal is 3G-B-DL.
BINARY:
The parallel-converted data is displayed in binary.
This option cannot be selected when the input signal is 3G-B-DL.
STREAM1: Stream 1 is displayed.
This option can be selected when the input signal is 3G-B-DL.
STREAM2: Stream 2 is displayed.
This option can be selected when the input signal is 3G-B-DL.
STREAM12: Streams 1 and 2 are combined and displayed.
This option can be selected when the input signal is 3G-B-DL.
Figure 13-4 Selecting the display format