4. HOW TO USE
21
The channels that you can apply signals to differ depending on the type of input signal as
shown below.
The signal switching method is relay for channels 1 and 2 and electronic switch for
channels 3 to 11.
If the specified signal is not received, it will be detected as a fault. For channels that will not
receive signals, set SW1 to SW3 to OFF.
If you specify user-defined setting 1 or 2, you can set the fault detection level to a value that
you want to use.
Reference
4.5.6, “Setting the Fault Detection Level (User-defined)”
“X” in the table indicates that the switch can be set to ON or OFF.
Table 4-2 Setting the channel 1 to 11 input signals
Input Signal
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 Input Channel
NTSC black burst signal
ON
OFF
OFF
X
X
X
X
X
Ch1 to 8
PAL black burst signal
OFF
ON
OFF
X
X
X
X
X
Ch1 to 8
HD tri-level
sync signal
720P/60
ON
ON
OFF
ON
OFF
X
X
X
Ch1 to 8
720P/59.94
ON
ON
OFF
ON
OFF
X
X
X
720P/50
ON
ON
OFF
ON
OFF
X
X
X
720P/30
ON
ON
OFF
OFF
ON
X
X
X
720P/29.97
ON
ON
OFF
OFF
ON
X
X
X
720P/25
ON
ON
OFF
OFF
ON
X
X
X
720P/24
ON
ON
OFF
OFF
ON
X
X
X
720P/23.98
ON
ON
OFF
OFF
ON
X
X
X
1080i/60
OFF
OFF
ON
ON
OFF
X
X
X
1080i/59.94
OFF
OFF
ON
ON
OFF
X
X
X
1080i/50
OFF
OFF
ON
ON
OFF
X
X
X
1080P/30
OFF
OFF
ON
OFF
ON
X
X
X
1080P/29.97
OFF
OFF
ON
OFF
ON
X
X
X
1080P/25
OFF
OFF
ON
OFF
ON
X
X
X
1080P/24
OFF
OFF
ON
OFF
ON
X
X
X
1080P/23.98
OFF
OFF
ON
OFF
ON
X
X
X
SD-SDI signal (270 Mb/s)
ON
ON
ON
X
X
X
OFF
OFF
Ch1 and 2
HD-SDI signal (1.485 Gb/s)
ON
ON
ON
X
X
X
ON
OFF
Ch1 and 2
3G-SDI signal (2.97 Gb/s)
ON
ON
ON
X
X
X
OFF
ON
Ch1 and 2
AES/EBU Digital Audio Signal
ON
ON
ON
X
X
X
X
X
Ch9 and 10
Word-clock signal
ON
ON
ON
X
X
X
X
X
Ch11
User setting 1
ON
OFF
ON
X
X
X
X
X
Ch1 to 11
User setting 2
OFF
ON
ON
X
X
X
X
X
Ch1 to 11
No input signal
OFF
OFF
OFF
X
X
X
X
X
Ch1 to 11