WARRANTY 

 

LEADER

 equipment benefits from a limited contractual warranty from the date of the purchase, 2 years parts and labour 

(excluding shipping and travelling fees). Normal wear parts are excluded from this warranty. 
 
This warranty is specifically limited to replacing or repairing the equipment (or its parts) which after examination proves to 
be defective for causes attributable to 

LEADER

.  

To claim under a warranty, the user (with 

LEADER

’S approval) will need to return the equipment to 

LEADER

, ZI des 

Hautes Vallées, Chemin n° 34, CS 20014, 76930 Octeville Sur Mer, France as soon as possible following the discovery of 
the defect. 
 
 
 
After reviewing the equipment: 
 

If the defect is attributable to 

LEADER

, it will repair it and assume the costs (excluding shipping and travelling fees), 

If the defect is not attributable to 

LEADER

, see the procedures laid down in the out-of-warranty Defect paragraph. 

 
 
This warranty does not commit 

LEADER

 in the following cases: failures resulting from improper handling, improper use 

of  the  equipment,  no  maintenance  or  incorrect  maintenance,  incident  affecting  the  hardware,  repair  or  modification  by 
another company or non-authorised personnel.  
 
 

OUT-OF-WARRANTY DEFECT OR EQUIPMENT NO LONGER COVERED BY THE WARRANTY  

 
A complete diagnostic will be conducted on your defective equipment, at the end of which a detailed estimate will be sent 
to you for the necessary repairs. 
For  failures  and  repairs  no  longer  covered  by  the  warranty,  a  diagnostic  flat  rate  will  be  applied  regardless  of  the 
acceptance of the repair quote. 

 

 

 

 

 

 

 

 

 

Summary of Contents for I40.90.110

Page 1: ...1...

Page 2: ...1000 lpm 2 5 BSP F F Mod le Fixe Avec pupitre de commande installer sur v hicule ou en installation fixe I40 90 118 Leader MIX CLASSE B AR CLASSE A 50 275 gpm 2 5 NH F M Portable Model I40 90 119 Lead...

Page 3: ...INSTRUCTIONS 8 7 SETUP 8 7 1 Portable Model 8 7 2 Fixed Model 10 7 2 1 Body 10 7 2 2 Remote controle console 12 7 2 3 Typical example of a fixed installation 13 7 2 4 Use 13 8 MAINTENANCE OPERATIONS...

Page 4: ...etwork flow The Portable model is equipped with a pressure meter and a suction indicator The Fixed model is equipped with a remote console It works similarly to in line venturi injectors it replaces 3...

Page 5: ...selector Output swivel connector Input swivel connector Suction connection Front Remote console Control Front Remote console Connection Fixed Model Portable Model Purge button Handle Suction indicator...

Page 6: ...se the device without having provided them with the necessary instructions Do not leave water inside the system if the temperature falls below 0 C risk of freezing 4 USAGE PRECAUTIONS Note The Leader...

Page 7: ...temperature Above freezing to 50 C 122 F Pressure loss 35 Flow indicator Yes No Input pressure meter Yes Yes On the remote control console Handle Yes No Suction tube Storz D connection No Check valve...

Page 8: ...rm LEADER immediately Ensure that each person responsible for the device using this device has read the user instructions and safety guidelines 7 SETUP 7 1 Portable Model 1 Place the Leader Mix CLASSE...

Page 9: ...d the operating indicator that the usage range is correct See graph on page 8 Minimum 5bars 200 L min 70psi to 50gpm Maximum 16bars 1050 L min 230psi to 280gpm 5 Connect the suction tube pipe to the L...

Page 10: ...odel 7 2 1 Body The Leader Mix CLASSE B AR CLASSE A 200 1000 l min 50 275 gpm will be mounted on the vehicle or fixed installation so the user is able to select the desired concentration on the dosing...

Page 11: ...16ft fig 1 then mount the valves fig 2 and ensure that they are sealed correctly Foam concentrate input and foam concentrate rinsing valves Before use close the water input output purge valves and the...

Page 12: ...e will depend on the distance between Leader MIX CLASSE B AR CLASSE A 200 1000 l min 50 275 gpm and control panel To connect control panel to Leader MIX CLASSE B AR CLASSE A 200 1000 l min 50 275 gpm...

Page 13: ...tage Dosing selector Foam concentrate tank Max height 1 5m 4 92ft Air comprim 2 way valve not supplied 3 way valve not supplied Check valve not supplied Pipe Not supplied Purge DN32 0 10ft or DN40mm 0...

Page 14: ...t valve 3 Use of the remote controle console I Injection mode Flow Foam II Bypass mode Flow Water Stops injection and reduces pressure drops below 800 l min 211 4gpm III flush mode Flush Water Foam co...

Page 15: ...rised 6 bars 87psi maximum and turn the dosing selector dial round twice whilst pressing and holding the purge button Water will then be directed through the foam concentrate circuit to clean it and t...

Page 16: ...ole valve to Flush several seconds whilst completing several full turns of the dosing selector Position the console valve back to Flow 3 Drain See Fixed installation diagram on page 13 Shut off the Le...

Page 17: ...debris sand stones at the injector input If there are impurities or debris stones sand inside the injector turn to Water position 5mm debris can be removed Check the water pressure it must be above 5...

Page 18: ...fect is attributable to LEADER it will repair it and assume the costs excluding shipping and travelling fees If the defect is not attributable to LEADER see the procedures laid down in the out of warr...

Page 19: ...19...

Page 20: ...20 Package leaflet code Leader MIX CLASSE B AR CLASSE A 200 1000 l min ZN5 2 EN 0...

Reviews: