Camloc 1/4 turn fasteners
Safe mechanical quick release
fastener systems
Locking/unlocking by quarter turn
Hand operated
Service-friendly, time-saving
and cost cutting
Vibration-resistant
-
-
-
-
-
Mechanical mounting of LL STAGE 6-24D
03.4 Control data connection
Control data cable length is specified by Norm IEC929 Annex E4.
It is not necessary to open the fixture before connecting of DMX512 control sig-
nal. Interconnections are realized by Neutrik XLR 5pin In/Out connectors.
Pin connections:
Pin 1 – ground
Pin 2 – signal negative
Pin 3 – signal positive
-
-
-
03.5 DMX channels
These informations are subject to change, latest data are on: www.leaderlight.eu
Order
code
Product name
LL76 085.1
LL STAGE 6-24D W VO, 15°
LL36 085.1
LL STAGE 6-24D W, without optic
LL76 095.1
LL STAGE 6-24D RGBA VO, 15°
LL36 095.1
LL STAGE 6-24D RGBA, without optic
Accessories
Order
code
Product name
LL37 220.1
LL FRAME STAGE 6 SQ6
LL37 230.1
LL FRAME STAGE 6 R6
LL77 200.1
LL VARIO OPTIC STAGE 6 15°
LL77 201.1
LL VARIO OPTIC STAGE 6 30°
LL77 202.1
LL VARIO OPTIC STAGE 6 40°
LL77 203.1
LL VARIO OPTIC STAGE 6 60°
LL77 204.1
LL VARIO OPTIC STAGE 6 EL (20°x40°)
LL36 300.1
LL BRACKET STAGE 6 SERIAL
LL36 320.1
LL BRACKET STAGE 6 PARALLEL DUAL (2pcs)
LL36 330.1
LL BRACKET STAGE 6 FIX
LL36 340.1
LL BRACKET STAGE 6 ADJUSTABLE
LL90 000
W-DMX MODUL 2,45GHz /5,8GHz DMX/RDM supply with W-DMX antenna
04 MAINTENANCE AND SERVICE
Before any maintenance is necessary to carefully read all
SAFETY INFORMATION 01!
Damages caused by inadequate cleaning or maintenance are not covered by warranty.
Requires periodic cleaning (dust, dirt ,...)
Procedure for maintenance:
Unplug mains before maintenance and at least 10 minutes cool off.
Appliance do not illegal open or demount.
Clean-up dust only from outer surface. Use vacuum or dumpy duster (warm
water)
Before reinstalling make sure everything is intact and dry– no wet parts!
Service:
Customer service provided by the manufacturer.
-
-
-
-
-
-
-
-
!
Ch.
W
RGBA
Mode1
1
W1
R1
2
W2
G1
3
W3
B1
4
W4
A1
5
W5
R2
6
W6
G2
7
B2
8
A2
9
R3
10
G3
11
B3
12
A3
Mechanical mounting of frame to the LL STAGE 6-24D
2.1 The screws unlock by hand. Pick out the frame.
Frame installation without tools (Figures Nr. 2.1 to 2.2).
180°
AIMING POSSIBILITY
The fixture could be aim to wish position with
adjustable bracket.
Mounting on stage is easy using various accessories as seen below (Figures Nr. 1.1 to 1.2). The brackets are connect by Camlocs.
1.1 Serial connection by LL36 300 for creation of continuous line
1.2 Parallel connection by dual bracket LL36 320
LL36 320
LL36 300
LL37 230
LL37 220
2.2 Insert the new framee. Apply the screws by hand.
VarioOptic LL77 200 ÷ 204
Mechanical mounting of VarioOptic to the LL STAGE 6-24D
2.3 The screws unlock by hand. Pick out the VarioOptic.
Insert the new VarioOptic. Apply the screws by hand.