Leader
Evaporator
Springtech
EXTREME
6
Reverse
Osmosis
System
Manual
Page:
52
13.
Position
breakers
CB1,
CB2,
CB3,
CB4,
CB5
and
CB6
to
the
ON
position.
14.
Close
the
control
box
cover
and
turn
the
latches
to
fasten.
15.
Run
a
rinse
cycle
(see
page
31)
until
a
minimum
of
1800
US
gallons
of
water
have
been
processed.
Near
the
end
of
the
rinse
cycle
turn
valve
V19
down
and
fill
the
wash
tank
2/3
full.
Return
valve
V19
to
its
original
position.
16.
Run
a
hot
water
wash
cycle
(see
page
34).
17.
Repeat
the
rinse
cycle
(see
page
31)
again
filling
the
wash
tank
as
specified
then
add
R/O
soap
(LEADER
Order
#
69992)
to
the
wash
tank
and
mix.
Mix
alkaline
R/O
soap
with
the
liquid
in
the
wash
tank
until
the
required
pH
is
reached.
To
determine
the
required
pH,
refer
to
the
Machine
Serial
Number
Data
Sheet
that
initially
accompanied
the
system.
NOTE:
If
the
membrane
is
changed,
reference
the
data
sheet
accompanying
the
new
membrane.
18.
Run
an
alkaline
wash
cycle
(see
page
34).
19.
Perform
a
rinse
cycle
(see
page
31)
using
a
minimum
of
1800
US
gallons
of
water.
20.
Perform
a
permeability
test
(see
page
22).
a.
Compare
the
results
to
the
results
of
the
test
when
the
system
was
new.
If
the
results
are
not
acceptable
contact
LEADER
EVAPORATOR
or
your
local
Distributor
/
Dealer
for
assistance.
b.
Record
the
results,
if
acceptable,
and
use
these
results
as
the
reference
for
test
for
the