Installation
To install the device, perform the following steps:
CAUTION!
Install a suitable fuse in the vehicle (up to 16 A).
1. Route a connection cable (H07RN-F, 3 x 2.5) in the vehicle.
2. Attach the connection cable to the vehicle installation.
3. Pierce the housing seal at the intended location with a pointed tool.
4. Feed the connection cable (H07RN-F, 3 x 2.5) through the hole.
5. Connect the wires of the connection cable to the corresponding screw
terminals.
ð
The device is installed.
Optional: Connect the immobiliser to the potential-free
switching contact (normally open contact)
To connect the immobiliser, proceed as follows:
CAUTION!
Install a suitable fuse in the vehicle (up to 1 A).
1. Route a cable (H05RN-F, 2 x 0.5) for the immobiliser in the vehicle and
connect it to the specific vehicle installation (control module or sim-
ilar).
2. Insert the immobiliser cable (H05RN-F, 2 x 0.5) through the second hole
of the housing seal.
3. Insert the wires of the immobiliser cable into the push-in terminals
(max. current: 1 A).
ð
The immobiliser is connected.
Assembly
1
2
3
4
5
1
Cover
2
Housing with body seal
3
Housing seal
4
Cap
5
Retaining screw
To install the device, proceed as follows:
1. Place the housing seal in the cap.
2. Attach the cap to the supply unit with the 3 screws (3.5 x 14).
3. Check the tightness of the housing seal.
4. Push the supply unit into the body cutout.
5. Tighten the 3 screws on the front until the supply unit is firmly seated
in the body cutout (maximum torque: 1 Nm).
6. Attach the cover.
ð
The device is mounted and ready.
Operation
NOTE!
An inactive immobiliser can cause equipment damage. The im-
mobiliser only works when the MelfBox is active (operating display lit up).
1. Plug the two-pin earthed plug of the connection cable into a 230-V
mains supply.
2. Open the flap of the supply unit.
3. Plug the coupling into the supply unit.
ð
The voltage input is provided at the load output of the supply unit.
Connected consumers are supplied. The operating display shows the
operating status of the MelfBox.
LED
Operating status
Blue,
flashing
The MelfBox is active. A minimum of 50 W power is removed
from the supply unit (the greater the power, the faster the
flashing).
Yellow,
Steady light
The MelfBox is active. No power is removed.
– Check the connection of the consumers.
– Check the fuse at the outlet of the MelfBox.
Disposal
Dispose of the device in accordance with the Waste Elec-
trical and Electronic Equipment Regulations (WEEE).
The system must not be disposed of with household
waste. Take it to a recycling point or return it to your point
of sale.
EU Declaration of Conformity
The MelfBox complies with the requirements of the follow-
ing directives:
– 2014/30/EU: EMV
– 2011/65/EU: RoHS
LEAB Automotive GmbH
//
Thorshammer 6
//
24866 Busdorf