background image

5 Package Contents

Item

No.

Battery charger

1x

User manual

1x

6 Assembly

To assemble the device, proceed as follows:

ü

Choose a cool, dry and well-ventilated assembly site.

ü

Do not mount the device directly next to or above batteries.

ü

Guarantee adequate cooling for an unimpeded supply of cooling air.

1. Fasten the device to the side holes (5 mm Ø) on a flat surface.

ð

The device is assembled.

7 Setting the Charging Parameters

The RBC charger contains 30 different charging parameters (charging charac-

teristic, battery capacity and charging mode) which you can select before con-

necting to the battery. A graphical illustration of the charging characteristics
can be found in 

Appendix [

}

 22]

.

To set the charging parameters, proceed as follows:

ü

Before setting, select the desired settings using the table below.

ü

The charger is disconnected from the 230 V mains.

ü

The charger is not connected to the battery.

1. Connect the mains plug to a 230 V mains supply.

2. As soon as the 'Ready for operation' LED lights up blue (after approx. 5 s),

press the STOP button for 10 s until all LEDs are flashing briefly.

ð

You are in configuration mode.

NOTE! 

When first used, charging parameters 1 (charging characteristic

LK10-06) and 9 (battery capacity 50 Ah) are preset by default.

3. To select a parameter from the list, keep pressing the STOP button until you

reach the desired position.

12

LEAB Automotive GmbH

Thorshammer 6

24866 Busdorf

7 Setting the Charging Parameters

LEAB Automotive GmbH

Summary of Contents for 0101036081

Page 1: ...www leab eu USER MANUAL VERSION 3 22 06 2021 CHARGER RBC IP54 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf...

Page 2: ...ackage Contents 12 6 Assembly 12 7 Setting the Charging Parameters 12 8 Checking the Charging Parameter Settings 15 9 Changing charging parameters 16 10 Installation 16 11 Operation 19 11 1 Switching...

Page 3: ...damage The signal word Attention indicates that there is a possibility of material damage To avoid material damage follow the instruction CAUTION Danger that can lead to minor injuries Safety instruc...

Page 4: ...evice solely in accordance with its intended use Any modifications to the device or its com ponents are prohibited and do not conform to its intended use Observe the safety instructions Keep this manu...

Page 5: ...ged and the electrolyte is not frozen 2 2 Foreseeable Misuse The charger is designed for Interior use in vehicles Never assemble the char ger outside the vehicle The charger is designed to charge all...

Page 6: ...id lead gel and AGM batteries 2 3 4 5 6 7 8 1 Fig 1 RBC charger front view 1 Data connection LED 2 Stop button 3 F1 button 4 F2 button no function 5 Ready for operation LED 6 Charging complete LED 7 C...

Page 7: ...onnection side 1 Mains connection cable of the charger 2 Charging cable red 3 Charging cable blue 4 Battery data line 5 Mounting bracket 7 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf LEAB Automot...

Page 8: ...13 5 V 13 8 V 13 5 V 13 8 V Input values 230 V 50 Hz 230 V 50 Hz Input voltage 195 V 264 V 195 V 264 V Input frequency 47 Hz 63 Hz 47 Hz 63 Hz Degree of efficiency max 93 93 International Protection...

Page 9: ...27 0 V 27 6 V Input values 230 V 50 Hz 230 V 50 Hz Input voltage 195 V 264 V 195 V 264 V Input frequency 47 Hz 63 Hz 47 Hz 63 Hz Degree of efficiency max 93 93 International Protection IP class IP54 I...

Page 10: ...27 0 V 27 6 V Input values 230 V 50 Hz 230 V 50 Hz Input voltage 195 V 264 V 195 V 264 V Input frequency 47 Hz 63 Hz 47 Hz 63 Hz Degree of efficiency max 93 93 International Protection IP class IP54...

Page 11: ...27 0 V 27 6 V Input values 230 V 50 Hz 230 V 50 Hz Input voltage 195 V 264 V 195 V 264 V Input frequency 47 Hz 63 Hz 47 Hz 63 Hz Degree of efficiency max 93 93 International Protection IP class IP54...

Page 12: ...harging characteristics can be found in Appendix 22 To set the charging parameters proceed as follows Before setting select the desired settings using the table below The charger is disconnected from...

Page 13: ...4 V is permanently output as standard in the Power Sup ply charging modes If you require a higher voltage please contact LEAB directly Charging mode Settings Charging mode default 25 Charging mode OFF...

Page 14: ...Fig 4 Charging parameter settings 14 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf 7 Setting the Charging Parameters LEAB Automotive GmbH...

Page 15: ...ights up orange The charging characteristic is set and saved Check the battery capacity setting To check the battery capacity settings proceed as follows 4 Keeping pressing the Stop button until you a...

Page 16: ...g the Charging Parameters 12 The charging parameters are changed 10 Installation Battery Connection To install the device in the vehicle proceed as follows 1 Disconnect the battery from the on board p...

Page 17: ...at tery optimally To connect the sensor cable proceed as follows NOTE When connecting pay attention to the instructions and notes in the sensor cable installation instructions 1 Connect the sensor cab...

Page 18: ...wire ends of the external LEDs to pin 4 pin 5 pin 14 and pin 22 The external LEDs are connected EBrix Connection 24 V You can connect the RBC 24 V charger to the eBrix system using a suitable ad apter...

Page 19: ...ector 2 Connect the wire ends to pin 26 pin 9 and pin 18 3 Plug the D sub connector into the connector for the CBL control relay on the device The CBL control relay is installed 11 Operation 11 1 Swit...

Page 20: ...ger begins to charge the battery as soon as the charger is connected to the 230 V mains Interrupting the Charging Process To interrupt the charging process proceed as follows 1 To interrupt charging p...

Page 21: ...nd the charger is se cure NOTE For battery maintenance refer to the battery manufacturer s instruc tions 13 Disposal Dispose of the device in accordance with the Waste Elec trical and Electronic Equip...

Page 22: ...tery results in 20 A LK10 05 Freely ventilated lead acid Fig 6 Charging characteristic LK10 05 In the Top Fill charging phase the battery is charged with 15 more current compared to the main charging...

Page 23: ...35 C and 45 C 60 C the current is reduced to 0 In the maintenance phase the battery voltage is checked periodically if the battery voltage falls below 2 17 V per cell the battery is charged for 2 minu...

Page 24: ...the charging process In the range 30 C 35 C and 45 C 60 C the current is reduced to 0 In the maintenance phase the battery voltage is checked periodically if the battery voltage falls below 2 17 V pe...

Page 25: ...attery is connected to the charger for 16 h the battery is charged with a 30 hour equal isation charge a current of 0 006 C and a voltage of 2 8 V per cell Voltage per cell 12 V system 24 V system 2 3...

Page 26: ...ontains a detection for weak batteries 0 5 V per cell Make sure that you do not charge batteries with a smaller num ber of cells For example do not charge a 12 V battery with a 24 V charging character...

Page 27: ...s a detection for weak batteries 0 5 V per cell Make sure that you do not charge batteries with a smaller num ber of cells For example do not charge a 12 V battery with a 24 V charging characteristic...

Page 28: ...contains a detection for weak batteries 0 5 V per cell Make sure that you do not charge batteries with a smaller num ber of cells For example do not charge a 12 V battery with a 24 V charging characte...

Page 29: ...29 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf LEAB Automotive GmbH 15 Appendix...

Page 30: ...30 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf 15 Appendix LEAB Automotive GmbH...

Page 31: ...31 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf LEAB Automotive GmbH 15 Appendix...

Page 32: ...sdorf Tel 49 0 4621 9 78 60 0 Fax 49 0 4621 9 78 60 260 info leab eu We make energy mobile It is prohibited to copy duplicate translate or otherwise pass on the content of this guide to third parties...

Reviews: