15 Appendix
Charging Characteristics
NOTE!
To select the correct charging characteristic for your battery, refer to
the instructions of your battery manufacturer.
NOTE!
The current, compared to the nominal capacity, is given in coulombs
(C), e.g. 0.2 C for a 100 Ah battery results in 20 A.
LK10-05 - Freely ventilated lead-acid
Fig. 6: Charging characteristic LK10-05
In the “Top-Fill” charging phase, the battery is charged with +15% more current
compared to the main charging phase.
In the range [-30 °C ... -35 °C] and [+45 °C ... +60 °C] the current is reduced to
0.
Voltage per cell
12 V system
24 V system
2.4 V/ 2.8 V/ 2.29 V
14.4 V/ 16.8 V/ 13.74 V
28.8 V/ 33.6 V/ 27.48 V
22