background image

*** The Flat Cable that connects the Main Controller to the    Water 
Tank is attached at the factory. This cable is fragile and may tear easily. 
The following instructions are how to connect the Flat Cable to avoid 
any damage. ***

 

 
 
 
 
 
 

 
 
 
 
 
 

   To connect the cable to the Main Controller unit, follow these in-
structions

 

 

A.

 

Open the back cover on the Main Controller unit and gently ex-
tend the cable lock out to plug in the Flat Cable head. The cable 
should have the blue side facing up and be positioned in the cen-
ter.

 

B.

 

Push the cable lock in to secure the Flat Cable head.

 

C.

 

Replace the back cover.

 

D.

 

Open the back cover on the fan enclosure and pull the cable lock 
out to plug in the Flat Cable head. The cable should have the blue 
side facing up and be positioned in the center. 

 

E.

 

Push the cable lock in to secure the Flat Cable head and    replace 
the back cover.

 

Connection Information 

 

Summary of Contents for iCigar Pro DCH-67

Page 1: ...CB FT humidors Up to 110 CB FT w sub tank not included Two Powerful and quiet fans Back lit liquid crystal display 1 Humidity sensor 2 Flat power cable 3 Power port for support slave unit 4 Air out ventilation 5 Air in ventilation 6 Water sensor 7 Power light 8 12V power port 9 Control buttons 10 Reset memory button 11 Support Leg 12 MP XS AP ports are for future features 13 Bluetooth Adapter Port...

Page 2: ... Controller unit and gently ex tend the cable lock out to plug in the Flat Cable head The cable should have the blue side facing up and be positioned in the cen ter B Push the cable lock in to secure the Flat Cable head C Replace the back cover D Open the back cover on the fan enclosure and pull the cable lock out to plug in the Flat Cable head The cable should have the blue side facing up and be ...

Page 3: ...n for 3 seconds until the RH setting numbers flash in the bottom right of the screen 2 Release the MODE button and use the UP and DOWN buttons to raise or lower the target humidity RH setting The humidifier fan will turn on and off depending on what the RH setting is set to Quickly press MODE to switch from C or F Press UP or DOWN to display the Max Min humidity When the water level becomes low th...

Page 4: ...Each Le Veil humidifier is equipped with a capacitive humidity sensor the same used in commercial laboratories Most digital hygrometers available are equipped with resistive sensors which can have a RH variance of 10 Please make sure the hygrometer used to match humidity has a capacitive humidity sensor To calibrate the iCigar Pro humidifier hold the MODE button keep holding it and before the numb...

Reviews: