V 1.2
11
NOTE: It may show “disabled” dependent on DMX Mode.
8)
Heater Mode (Advanced Option):
The heater can be turned on/off on the G300-Smart. This is mainly for set
installations where the machine might be left on for hours, perhaps 24/7. The
heater is able to be controlled by the machine itself in “auto” mode (usual
operation), or DMX (assign a DMX channel as well), or via the LeMaitre MIP from
the client program.
9)
Heater DMX Channel (Advanced Option):
Set the DMX channel for controlling the heater.
NOTE: Only used if the Heater Control Mode is on DMX, otherwise irrelevant what
setting it is on.
10)
Enable Remote (Advanced Option)
:
The legacy Gforce2/3 Timer remote can be used with the G300-Smart, plugged into
the DMX IN/REMOTE port. In order for the remote to have power, it must be
enabled from this setting.
11)
Fluid Out Sensor (Advanced Option)
:
There is an optical Fluid Out Sensor on the input fluid tube, in order to detect and
cut out the machine if running dry. This sensor is calibrated in the factory, but in
the event that it is not working correctly and perhaps incorrectly disabling the
machine, it can be disabled from this setting. Contact LeMaitre if this occurs.
12)
Fluid Level Sensor (Advanced Option)
:
A fluid sensor is present and attached to the fluid bottle cap. Once calibrated
correctly for the fluid type, it can provide fluid level readings. It will report a
warning and flash up a low fluid message on the display should the fluid level drop
below a certain level. If this is not required, then it can be disabled from this
setting. The fluid level sensor is disabled by default.
13)
Errors (Advanced Option)
:
Shows the number of errors, and displays error messages for each one. Use the
Diagnostics page on the Web Server Interface for more detailed error information.
14)
Connectivity Mode (Advanced Option)
:
The machine is able to connect to external networks, and to the internet. The
connectivity mode can be changed in order to achieve the desired connection type.
If you wish to scan for external networks, enable the Wi-Fi module by selecting
“WIFI AP ENABLED” – from there you will be able to join the access point, access
the web server, and run the ‘Scan and Connect’ procedure.
See page 17 for more information on “Connectivity Modes”.
15)
0-10V Mode (Advanced Option)
:
Similarly to the DMX mode, the 0-10V interface has 3 modes (0-2) of operation.