Description for Kabel Light@Night:
If you use the PC-light control
Light@Night
or the Layout-light control
Light-DEC
and you do not want to connect the Light-Display
respectively Light-Power Module directly onto each other but prefer the installation of the module at a larger distance you can use the
Kabel
Light@Night
with a length of 1 meters.
Insert the pin-plug connector of the connection cable with the pin plug into the 10-poles socket bar of the previous Light-Display-
respectively Light-Power Module at a position that the white single wire of the connection cable corresponds to the white marking at the
Light-Display- respectively Light-Power Module.
The other side of the cable has to be connected to the 10-poles pin-plug of the next module. Also on this side it has to be assured that
the white single wire of the connection cable corresponds to the white marking at the Light-Display respectively Light-Power Module.
The following draft shows the correct connection of the connection cable. The cable has to be directed to the top.
weiss
white
weiss
white
1m
Stiftleiste (Adapter)
pin plug (adapter)
Bestellbezeichnung /
Order code: Kabel Light@Night 1m
Light Interface (LPT)
Rev. 1.0
Littfinski DatenTechnik (LDT)
BU1
IC2
IC3
IC
4
B
U
2
IC
1
C2
C1
Printer
Port
LPT
white
weiss
white
weiss
KL4
KL3
KL2
KL1
KL7
BU1
ST1
4
5
6
7
8
2
6
2
7
2
8
2
9
3
0
3
1
3
2
2
5
9
1
0
11
1
2
1
3
1
4
1
5
1
6
1
8
1
9
2
0
2
1
2
2
2
3
2
4
1
7
1
2
3
G
B
S
-D
is
p
la
y
/
L
ig
h
t-
D
is
p
la
y
L
itt
fin
s
k
i
D
a
te
n
T
e
c
h
n
ik
(L
D
T
)
KL5
b
ra
u
n
g
e
lb
10...18V~
12...24V=
KL6
BU2
IN
3
9
3
8
3
7
3
6
3
5
3
4
3
3
4
0
BU3
O
U
T
R
e
v
.
1
.8
white
weiss
white
weiss
KL4
KL3
KL2
KL1
KL7
BU1
ST1
4
5
6
7
8
2
6
2
7
2
8
2
9
3
0
3
1
3
2
2
5
9
1
0
11
1
2
1
3
1
4
1
5
1
6
1
8
1
9
2
0
2
1
2
2
2
3
2
4
1
7
1
2
3
G
B
S
-D
is
p
la
y
/
L
ig
h
t-
D
is
p
la
y
L
itt
fin
s
k
i
D
a
te
n
T
e
c
h
n
ik
(L
D
T
)
KL5
b
ra
u
n
g
e
lb
10...18V~
12...24V=
KL6
BU2
IN
3
9
3
8
3
7
3
6
3
5
3
4
3
3
4
0
BU3
O
U
T
R
e
v
.
1
.8
Please pay attention:
The first Light-Display respectively Light-Power
Module has always to be connected directly to the Light-Interface
(LI-LPT or LI-LAN) the PC-Light-Control
Light@Night
respectively always directly onto the Basic-Module of the Layout Light-Control
Light-DEC
. Therefore is it only possible to use the connection cable
Kabel Light@Night
for the connection of the second to the first
Module.
Further products from the
Digital-Professional-Series
:
Kabel s88 0,5m / Kabel Light@Night 0,5m
Connection cable (0.5m)
for the s88-feedback bus and the Light Controls Light@Night and Light-DEC.
Kabel s88 2m / Kabel Light@Night 2m
Connection cable (2m)
for the s88-feedback bus and the Light Controls Light@Night and Light-DEC.
S-DEC-4
4-fold turnout decoder
for four magnet accessories with free programmable decoder addresses and possible external power supply.
SA-DEC-4
4-fold switch-decoder
with four bistable relays and free programmable decoder addresses and possible external power supply.
LS-DEC-DB, -DR, -KS, -ÖBB, -SBB, -NS, -NMBS, -BR, -FS, -SJ, -SNCF, -CFL, -USA, -CSD, -8x2
4-fold light signal decoder
. Light signals switched directly via decoder addresses.
RM-88-N / RM-88-N-O
16-fold feedback modules
for the s88-feedback bus.
RM-88-N-O
with integrated opto coupling.
RM-GB-8-N
8-fold feedback modules
with integrated track occupancy detectors for the s88-feedback bus.
HSI-88-(USB)
High Speed Interface
for the s88-feedback bus. Offers the possibility to create three feedback lines. The feedback reports will be
transmitted directly via the command station via the COM- (
HSI-88
) or the USB-Interface (
HSI-88-USB
) to the PC.
Made in Europe by
L
ittfinski
D
aten
T
echnik (
LDT
)
Bühler electronic GmbH
Ulmenstraße 43
15370 Fredersdorf / Germany
Phone: +49 (0) 33439 / 867-0
Internet: www.
ldt-infocenter
.com
Subject to technical changes and errors.
07/2019 by LDT
Märklin and Viessmann are registered trademarks