Mounting procedure TCU
Ref : C3131320010
Version : A1
3.
MAIN FEATURES
3.1.
E
LECTRONIC
F
EATURES
Power supply (5A fuse protected)
7 to 32 V
Operating current
1 A
Temperature operating range
-40°C to 85°C
Storage temperature range
0 to 30°C
Legal Regulations
R&TTE (99/5/EC)
FCC/IC
PTCRB
E marking
Antennas (GSM, GPS and RF)
Internal
3.2.
M
ECHANICAL
F
EATURES
Total Mass
256 g
Dimensions (L x W x H)
123 x 120 x 50 mm
Connector (10 Ways)
FCI - Delphi Connector APEX 150
Tightness
IP 68 & IP69K
Mounting
LDL Brackets (see §4)
Wiring
LDL harnesses (see §6)
3.3.
C
ONNECTOR
P
IN
O
UT
Pin number
Mnemonic
Function
1
CAN HI
CAN High
2
-
Reserved
3
CAN LO
CAN Low
4
BBM+
BBM positive
5
IGN
Ignition status (KL15)
6
-
Reserved
7
VBAT
Vehicle battery positive (KL30)
8
-
Reserved
9
GND
Vehicle battery negative (KL31)
10
TEMP
BBM temperature
C3131320010-A1-TCU_Mounting_Specification.odt
LDL Technology SAS – Toulouse – France
6/ 16
Copyrights 2015