PAGE 16
High/Low Relay Adjustment
In addition to being able to manually control the inductor and capacitor value of the AT-100Pro, it is
also possible to manually set the high/low impedance relay, which determines whether the tuner is an L-C
configuration or a C-L configuration. To toggle the state of the high/low impedance relay, press
Func ->
Ant
. The LED will display one of two patterns to confirm the setting.
Manual Memory Store
Once manual adjustments are complete, press
Func -> Tune (Store)
(that is, press
Func
momentarily,
then
Tune (Store)
momentarily) to store the current relay settings in the memory associated with the
frequency last transmitted upon.
Status Check
The status of most user settings can be checked by pushing and
holding
the
Func
button while
pressing the relevant button for that setting. For example, to check to see what the current SWR threshold
value is, without changing the value, press and hold the
Func
button, and while still holding the
Func
button, press the
L Dn
(Thresh)
button. The display will show the currently selected SWR threshold
value.
While holding the
Func
button, the bargraph display will show the following pattern, to indicate that
the AT-100Pro is waiting for you to push a button to check its status:
Summary of Contents for AT-100Pro