LDDE NanoPix Cyc Short Instruction Download Page 8

Page 8

Settings

Lighting

Design

Development

Electronics

LDDE Vertriebsgesellschaft m. b. H.
Simmeringer Hauptstraße 357, 1110 Vienna, Austria
P: +43 1 7671811 0, F: +43 1 7671811 99

E: [email protected]; W: www.ldde.com

LDDE Vertriebsgesellschaft GmbH reserves the right, without prior notice, changes to the product and specification

Test Mode

In this mode, the intensity is continuously scaled up and down from 0-100%, whereby the speed of the dimming 

process can be adjusted in 10 steps. The display shows a bar indicating the current speed.

In Test Mode three different test programs are available, see table below.

Use the Up / Down buttons to select the desired mode.

Use the Left / Right buttons to set the dimming speed.

Single

All colors are tested in sequence.

RGB

RGB is tested jointly.

RGBWWCW

All colors are tested simultaneously.

Standalone Mode

In this mode 10 fixed colors are available, which are selected with the Up / Down keys.

 

Use the Left / Right keys to change the brightness, which is displayed as a bar in the lower line of the display.

R

G

B

WW

CW

Magenta

255

0

255

0

0

Lavender

255

0

255

0

255

CT Blue

0

115

255

0

255

Light Green

0

255

84

118

0

Cyan

0

255

255

0

0

Yellow

255

255

0

0

0

Light Yellow

255

255

0

255

0

Amber

255

166

0

0

0

Warm White

255

216

0

255

255

Cold White

176

255

255

255

255

Control Channel

If the control channel is activated, various functions of the NanoPix Cyc can be switched on and off  

via an additional DMX channel.

Control:

 

1.

 Set the Control Channel to the respective value.

2.

 No value change for at least 3 seconds.

3.

 Then flash directly to 0.

4.

 New setting is saved.

PWM frequency 750 Hz

11 - 20 DMX value

PWM frequency 1500 Hz

21 - 30 DMX value

PWM frequency 3000 Hz

31 - 40 DMX value

Quiet Mode ON

101 - 110 DMX value

Quiet Mode OFF

111 - 120 DMX value

Fade to Zero ON

201 - 210 DMX value

Fade to Zero OFF

211 - 220 DMX value

Summary of Contents for NanoPix Cyc

Page 1: ...ing Design Development Electronics LDDE Vertriebsgesellschaft m b H Simmeringer Hauptstra e 357 1110 Vienna Austria P 43 1 7671811 0 F 43 1 7671811 99 E office ldde com W www ldde com LDDE Vertriebsge...

Page 2: ...r supply before re positioning and cleaning Ensure that when the luminaire systems are installed in decorations a sufficient clearance of around 30cm is required for adequate cooling and ventilation P...

Page 3: ...rm the appropriate system configuration on the unit using the control panel located on the top of the unit It is recommended to carry out all configurations in advance of the installation on the devic...

Page 4: ...on mode with all basic functions CH10 HIGH RESOLUTION COLOR MODE 10 CHANNELS Same as Ch5 Color Mode but with 16 bit dimming CH15 PIXEL MODE 15 CHANNELS 3 LED modules are individually controlled with 8...

Page 5: ...erves the right without prior notice changes to the product and specification Ch LED module 8 bit interpolated Ch 5 Ch 7 Ch 15 Ch 16 Ch 17 1 Intensity xxx 1 xxx 1 1 2 1 R red 1 2 1 2 2 3 G green 2 3 2...

Page 6: ...old white 9 9 9 9 10 cold white fine 10 10 10 10 11 2 red 1 1 11 11 12 red fine 2 2 12 12 13 green 3 3 13 13 14 green fine 4 4 14 14 15 blue 5 5 15 15 16 blue fine 6 6 16 16 17 warm white 7 7 17 17 18...

Page 7: ...strobe The NanoPix Cyc is then in the Ch7 Normal Mode and the following settings can be made directly in the menu using the selection keys I Intensity between DMX value 0 255 R Red of DMX value 0 255...

Page 8: ...Standalone Mode In this mode 10 fixed colors are available which are selected with the Up Down keys Use the Left Right keys to change the brightness which is displayed as a bar in the lower line of th...

Page 9: ...uiet Mode OFF PWM frequency 750 Hz Control Channel OFF Fade to Zero ON Display Rotate OFF Temperature 10 C The measured temperature is below 10 C XX C The measured temperature is shown in the display...

Page 10: ...gine RGB warm white cold white Average life span approx 30 000 hours Connections Input Output Neutrik PowerCon In Out XLR 5 pol In Out Electrical specifications Input voltage range 100 240VAC 50 60Hz...

Page 11: ...DDE Vertriebsgesellschaft m b H Simmeringer Hauptstra e 357 1110 Vienna Austria P 43 1 7671811 0 F 43 1 7671811 99 E office ldde com W www ldde com LDDE Vertriebsgesellschaft GmbH reserves the right w...

Page 12: ...rves the right without prior notice changes to the product and specification Distance 1 5m Distance 2 5m Distance 2 0m The following figures show the light distribution at different distances and posi...

Page 13: ...ctronics LDDE Vertriebsgesellschaft m b H Simmeringer Hauptstra e 357 1110 Wien Austria P 43 1 7671811 0 F 43 1 7671811 99 E office ldde com W www ldde com LDDE Vertriebsgesellschaft GmbH reserves the...

Reviews: