MPS-8Z connection to
an audio system with
ZES-22
Support Handbook
Installation of a network MPS-8Z microphone
to audio systems with SIME software
Review: 1
Page 1: ...MPS 8Z connection to an audio system with ZES 22 Support Handbook Installation of a network MPS 8Z microphone to audio systems with SIME software Review 1...
Page 2: ...detail that allows choosing the source of the power supply between local or supplied through the ACSI bus When the selector is in the OFF position the equipment will be powered locally by the external...
Page 3: ...ripe Blue RS 485 B 6 Green GND 7 Stripe Red 24 V 8 Red 24 V Table 1 Pinout of the RJ45 connector These connections must be made using three way Euro Block type connectors differentiating between the R...
Page 4: ...nput plus control signals for connection of up to 8 devices in daisy chain bus mode where each device is connected to the next Both connections are identical and interconnected This connection must be...
Page 5: ...upport Website 2 REQUIREMENTS For the correct operation of the system the following requirements must be met ZES 22 with firmware version 1 0 5 or higher To allow audio input to channel 3 of the ZES 2...