background image

 2.3.3  AUXILIAR POWER SUPPLY

The equipment has an auxiliary power supply. Emergency voltage is continue and has a

nominal   value  of  5V.  It  will  be  externally  supplied  through  an  USB  charger,  included  with  the
equipment (female miniUSB connector).

Mark

Description

Type

Signals Activation

POWER

USB

Auxiliar power supply input.

Port

USB 1.1

5V DC
Max Current:  see technicals 
characteristics (chapter 8 )

Table 3: 

Auxiliar power supply input

Connection is done through a male miniUSB cable, AB type (supplied with the system) 

 2.3.4  PORTS FOR EXPANSION KEYBOARDS

The equipment has two available ports for connecting additional keyboards, one on each

side of the unit. Only one of the ports can be used simultaneously. 

Mark Description

Type

Signals Activation

-

Expansion port

I/O

-

N/A

Table 4: Expansion port

 3  OPERATION DESCRIPTION:

 3.1  TURNING ON

Select  the  power  supply  origin  as shown on  4.1. Connect  the power  supply  cable  into

'POWER' connector located on the back side of the equipment, or directly through the ACSI bus.
On the frontal side of the equipment, a check indicators sequence will start. Once the sequence is
finished, linking with system process will start and it will be shown in the corresponding indicator.

When you turn on the equipment for the first time, you must make the typical installation

adjustments (see chapter 4)

 3.2  KEYBOARD LOCK

The MPS 8Z has an optional feature to lock the keyboard. To con figure key lock, please

see section 4.4.5. 

If any button is pushed during the key lock, the zone memory indicators will blink four times.  

LDA Audio Tech – 31 Severo Ochoa - 29590 MALAGA, Spain. Tel: +34 952028805

5

User's Manual: MPS 8Z

Summary of Contents for NEO MPS 8Z

Page 1: ...User s Manual Model MPS 8Z...

Page 2: ......

Page 3: ...7 4 CONNECTION AND SETTING UP 7 4 1 POWER SUPPLY 7 4 1 1 POWER SUPPLY SELECTOR 7 4 2 CONNECTION TO THE SYSTEM ACSI BUS 8 4 2 1 BUS TERMINATOR 8 4 3 MPS 8K EXPANSION KEYBOARDS INSTALATION 9 4 3 1 KEYBO...

Page 4: ...ulated by qualified personnel 8 Pay attention to the connection polarity when operating the equipment with a direct current DC power source The reversed polarity connection can cause damage to the equ...

Page 5: ...nes per memory 64 zones 2 Up to 64 zone memories with addressing of 8 zones per memory 512 zones by means of expansion keypads 3 8 memories for system events 4 Recall from latest live PA message 5 Din...

Page 6: ...the problem persists see chapter 6 4 for resolution Yellow color 2 1 2 STATUS INDICATORS OF THE CALL CHANNEL The status indicators per channel show at all times their status or operating condition d...

Page 7: ...st voice announcement message into the selected zone memories e ALL CLEAR The ALL CLEAR button is located to the right of the upper area of the keyboard Allows the selection of all available zone memo...

Page 8: ...VOICE ALARM SYSTEM ACSI LOOP The equipment has two connections for distributed elements in Public Address systems It consists of a line level audio input plus control signals for connecting up to 8 de...

Page 9: ...iption Type Signals Activation Expansion port I O N A Table 4 Expansion port 3 OPERATION DESCRIPTION 3 1 TURNING ON Select the power supply origin as shown on 4 1 Connect the power supply cable into P...

Page 10: ...ne 1 we can select Zone 1 and in the memory 2 the zone 2 The zones assigned to each zone memory can contain up to 8 zones of the system Thus one MPS 8Z can address up to 64 zones of the system and up...

Page 11: ...l If the system has been able to launch the event the CW indicator will blink twice 4 CONNECTION AND SETTING UP 4 1 POWER SUPPLY The MPS 8Z is provided with an external power supply of 5V DC A female...

Page 12: ...ng up of the LINK and EMG indicators The set bus adress will be indicated by lighting the indicator of the zone memory associated Push the memory selection button whose number corresponds with the des...

Page 13: ...follow the next steps Disconnect MPS 8Z from the ACSI bus and from the power supply Place the connection adapter supplied with the expansion keyboard on the chosen side and connect both the paging sta...

Page 14: ...Zones 57 64 ID 8 Zones 9 16 Selection not allowed by default it will assigned ID 1 ID 9 Zones 9 16 Selection not allowed by default it will assigned ID 1 ID 0 Zones 9 16 Selection not allowed by defa...

Page 15: ...igital Sound Adjustment is a Digital Voice Processing that automatically adjust the gain of the voices of different users When this function is enabled the zone 4 light will remain on To confirm the n...

Page 16: ...ipment will restart Configure the address accordingly see 4 2 If this procedure does not work disconnect the unit from the ACSI bus and contact LDA s Support Department Once the unit is removed if the...

Page 17: ...s Support Department RMA and ask for a replacement You can keep using the equipment while the gooseneck is being replaced by using an external microphone and following the steps of chapter 4 4 3 If t...

Page 18: ...Disconnect the first keyboard that is not switched on and connect the rest to the MPS 8Z If necessary re configure the address following chapter XX and the content of each zone through the System s Co...

Page 19: ...ated ring for conceded word Buttons 3 buttons for special functions Memory Events and Cancel Re call button Selection deselection button of all zones 8 zone memory buttons 1 Talk button Functions Gong...

Page 20: ...Ver 2...

Reviews: