LD LDXS200 User Manual Download Page 7

ConnECtionS, 

CONTROLS, AND INDICATORS:

1

CHANNEL A / CHANNEL B

Volume controls for Channels A and B. Always set the volumes to minimum before turning the equipment on 
or off. In bridge mode, the volume of the power amplifier is controlled by the volume control for Channel A.

2

POWER LED

Lights up once the speaker system is switched on and properly connected to the power mains.

3

SIGNAL LED A / B

The signal LEDs for Channels A and B light up as soon as there is an audio signal on the respective channel.

4

CLIP LED A / B

Lights up if the power amplifier is operating in the clipping range. Brief flashing is not critical. Permanent 
illumination should be avoided by reducing the volume (volume control 1), because otherwise distortion 
can result, which can have a negative influence on the sound on the one hand and, on the other, can cause 
damage to the connected speakers.

5

PROTECT LED A / B

Lights up after power-on as long as the power-on delay is active. After the Protect LED goes out, the power 
amplifier is ready for operation. 
The Protect LED lights up when one of the power amplifier protection circuits is active. To protect the power 
amplifiers and the connected speakers, the speaker outputs are deactivated in protect mode. Once the 
source of the trouble has been eliminated (e.g., overloading or a short circuit at the speaker output), after a 
short time, the power amplifier returns to normal status, the Protect LED goes out, and the speaker outputs 
are reactivated. If the Protect LED does not go out after a short time even if all inputs and outputs have been 
disconnected, there is an internal fault. In this case, turn off the power amplifier, disconnect it from the power 
mains, and hand it over to an authorised service centre.

7

IT

ALIANO

POLSKI

ESP
AÑOL

FRANCAIS

FRANCAIS

FRANCAIS

FRANCAIS

FRANCAIS

DEUTSCH

ENGLISH

1

2

3

4

5

6

7

8

1

Summary of Contents for LDXS200

Page 1: ...USER S MANUAL BEDIENUNGSANLEITUNG MANUEL D UTILISATION MANUAL DE USUARIO INSTRUKCJA OBS UGI MANUALE D USO PA POWER AMPLIFIER CLASS D LDXS200 LDXS400 LDXS700...

Page 2: ...sockets and screw terminals as outputs On the rear panel it is possible to select the mode of operation and gain and activate the limiter and ground lift function LEDs on the front indicate power sign...

Page 3: ...PA Power Amplifier CLASS D LDXS200 LDXS400 LDXS700 3 ITALIANO POLSKI ESPA OL FRANCAIS FRANCAIS FRANCAIS FRANCAIS FRANCAIS DEUTSCH ENGLISH...

Page 4: ...17 During transport make certain that the equipment cannot fall down and possibly cause property damage and personal injuries 18 If your equipment is no longer functioning properly if fluids or objec...

Page 5: ...ave repairs carried out only by qualified service personnel The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated danger...

Page 6: ...are unimpeded We recommend the use of high quality balanced cables with two conductors for the audio signal plus separate shielding mesh with XLR type connectors for connecting the signal source e g m...

Page 7: ...ther can cause damage to the connected speakers 5 PROTECT LED A B Lights up after power on as long as the power on delay is active After the Protect LED goes out the power amplifier is ready for opera...

Page 8: ...t stages A and B are connected to a more powerful mono output stage IMPORTANT In bridge mode the total impedance of the connected speaker system must not be less than 8 ohms NOTE If neither of the two...

Page 9: ...R In stereo mode power amplifier channels A and B operate independently Both stereo signals and entirely different signals can be amplified via Channel A and B PARALLEL MODE PAR One line input INPUT A...

Page 10: ...e to the black terminal clamp of the respective channel In bridge mode the red Channel A terminal clamp must used as the positive pole and the red Channel B terminal clamp must be used as the negative...

Page 11: ...mpatible connector pin assignments STR and par position stereo and parallel mode 11 ITALIANO POLSKI ESPA OL FRANCAIS FRANCAIS FRANCAIS FRANCAIS FRANCAIS DEUTSCH ENGLISH e l a m e f R L X e l a m R L X...

Page 12: ...WIRING EXAMPLE 12 ENGLISH DEUTSCH FRANCAIS FRANCAIS FRANCAIS FRANCAIS FRANCAIS espa ol POLSKI ITALIANO X S 2 00 X S 4 00 X S 7 00...

Page 13: ...n Limiter On Off Ground Lift Mode Volume Gain Limiter On Off Ground Lift Mode Volume Gain Limiter On Off Ground Lift Mode Indicators Clip Protect Bridge Mode Parallel Mode Signal Power Clip Protect Br...

Page 14: ...eight 3 kg 3 4 kg 3 4 kg Accessories included Power cord user manual Power cord user manual Power cord user manual Other features convection cooling temperature controlled fan temperature controlled f...

Page 15: ...the product In the event of repair or replacement during the Limited Warranty Period the replaced original parts and or pro ducts become property of Adam Hall In the unlikely event that the product wh...

Page 16: ...nty or as a tort claim including negligence and strict product liability a contract claim or any other claim and cannot be rescinded or changed by anyone This limitation of liability will be effective...

Page 17: ...d this product or their local government office for details on where and how they can recycle this item in an environmentally friendly manner Business users should contact their supplier and check the...

Reviews: