LCJ CAPTEURS CV3F series User Manual Download Page 2

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

        

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

61 

Principle of operation: how the equipment works 

 

The  sound,  the  ultrasonic  sound  is  conveyed  by  the  movement  of  the  fluid  in  which  it  crosses.  The 
electroaccoustic  transducers

1

  communicate  between  themselves  two  by  two  by  ultrasonic  signals

2

  to 

determine, following the orthogonal axes, the wave transit time differences induced by the air flow

3

The measurements are combined in an integrated calculator in order to establish the wind module and its 
direction  in  relation  to  a  reference  axis.  The  temperature  measurements  are  used  for  calibration 
corrections. 
CV7 Transducers communicate between themselves delivering four independent measures while head 
wind measured vectors are preferably used for calculations. 
This method gives a sensibility of 0,25 knots, a dynamic of 80 knots and an excellent linearity. 
The effect of an inclination

4

 of the wind sensor is partially corrected due to the shape given by the space.

      

Delivery contents : 

 

CV7 sensor 
Support and clamp 
25 m cable, 4 conductors 
User’s notice

 

CV7 Software configuration 

      Characteristics 

 

Numerical  output  signals  :  NMEA0183

®

,  MWV,  XDR  or 

specialised program. 
Wind sensor sensibility : 0,25 knots 
Resolution : 0,1 knots 
Wind sensor range : 0,25 to 80 knots  
Directional sensibility : +/- 1 degree 
Resolution : 1 degree 
Power supply : 10 to 14 V DC 12 mA 
Temperature range : -10 to 55 ° C 
Weather proofing : IP67 
Weight  of  the  head  :  150  g  (including  the  support  and  clamp  : 
230g) 

 

     Optional accessories : 

 

ST option : compatible with ST40, ST60 
BG option : compatible with network, Hydra, Hercule 
SIL options: compatible with NEXUS 
BARO option : measurement of the atmospheric pressure  
StatFixBaro : CV7 software program 
Vertical fixation adaptor for CV7

 

Numerical transmission speeds 4 800 or 38 400 baud / sec 

64 

      Programmable parameters : 

 

Angle correction in degrees 
Smoothing time constant of speed and direction: 1, 2, 4, 8, 16 s 
Speed units in knots, m/sec, km/h 
Temperature units Centigrade or Fahrenheit 
NMEA

®

 interface formats or specialised programs. 

 
    

 

EN 55022   EN 55024 

 

 

 

 

 

 

 

 

330mm 

80 

Summary of Contents for CV3F series

Page 1: ...nal sensor can be programmed and configured for angle correction smoothing time constants measurements units and interface formats LCJ CAPTEURS Z A le Ch ne Ferr 44120 VERTOU France www lcjcapteurs co...

Page 2: ...by the space Delivery contents CV7 sensor Support and clamp 25 m cable 4 conductors User s notice CV7 Software configuration Characteristics Numerical output signals NMEA0183 MWV XDR or specialised pr...

Page 3: ...allation NMEA 0183 Interconnexions NX2 NEXUS or FI30 FURUNO WIND DATA Instrument interconnexions NX2 NEXUS or FI30 FURUNO SERVER Interconnexions FI50 Fi501 FURUNO Interconnexions CV7 configuration Pie...

Page 4: ...ble red cable Connect the receiving display to the connector NMEA For a RS232 computer COM 1 entry Link NMEA to COM1 Rx Terminal 2 Link 0V to 0V the COM1 Terminal 5 If it s necessary link together the...

Page 5: ...t NX2 or FI30 SERVER Interconnexions 12VDC 0V 1 2 1 2 3 4 NEXUS WIND LOG 12VDC 0V 1 2 Power source 12 VDC 10 to 14VDC with fusible Power source 0 V SCREEN 13 WHITE 14 YELLOW 15 GREEN 16 4 SERVER CV7 R...

Page 6: ...reen Yellow Red Blue Power source 12 VDC 10 to 14VDC Red Black Power source 0 V FI 501 WIND NMEA 2000 NMEA 2000 12VDC OptFI50 interface CV7 Green Yellow Red Blue FI50 Dir1 Dir2 Speed V 0V FI50 Cable 2...

Page 7: ...com Configuration_CV7 Realise the following connexions Red cable power Blue cable power Yellow cable Green cable Decompress the file in the directory of your choice copy the shortcut to the office Do...

Page 8: ...Piercing gauge...