LED BAR8 V2

(LCG-003 V2) User manual

4

5.Main Function

LEDS: 240pcs (96pcs red, 72pcs green, 72pcs blue) 10mm LEDs

Beam angle: 25°

Black aluminum material

3 pin female XLR socket and 3 pin male XLR socket

U-Ground socket Power in & Power out

Maximun link number: 10pcs

LED display for easier operation.

Built-in programs, Auto running, DMX mode, M/S, sound-active mode, static color, IR Remote

DMX-512:30CH/25CH/25CH./24CH/18CH/12CH/9CH/4CH/4CH./3CH selectable channels

Power consumption: 18W

Power supply: AC100-240V 50/60Hz

Weight: 2.6kgs

Size: 1070*65*88mm

6. DMX Control Function

DMX Channels

30CH

CHANN

E L

NAME

CHANNEL NAME

1

DIM ALL

16

B5

2

R1

17

R6

3

G1

18

G6

4

B1

19

B6

5

R2

20

R7

6

G2

21

G7

7

B2

22

B7

8

R3

23

R8

9

G3

24

G8

10

B3

25

B8

11

R4

26

SHUT

Summary of Contents for LCG-003 V2

Page 1: ...www lc group ca USER MANUAL LED BAR8 V2 LCG 003 V2 240pcs RGB 8 section IR...

Page 2: ...Instructions 2 3 Installation 3 4 Outside Size Picture 3 5 Main Function 4 6 DMX Control Function 4 7 Display Operation instruction 9 8 Infrared keyboard operation 13 9 Troubleshooting 14 Please read...

Page 3: ...LCG 003 V2 is covered by tensile aluminum designed in a fashion of hydrodynamic form It uses high power R G B 3 kinds LED Each kind of LED can be independently dimmed It uses power switch performs low...

Page 4: ...base Maximum ambient temperature is TA 40 C Don t operate it where the temperature is higher than this The unit is for indoor use only Use only in a dry location Don t connect the device to any dimmer...

Page 5: ...ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the w...

Page 6: ...y for easier operation Built in programs Auto running DMX mode M S sound active mode static color IR Remote DMX 512 30CH 25CH 25CH 24CH 18CH 12CH 9CH 4CH 4CH 3CH selectable channels Power consumption...

Page 7: ...ME CHANNEL NAME 1 R1 14 G5 2 G1 15 B5 3 B1 16 R6 4 R2 17 G6 5 G2 18 B6 6 B2 19 R7 7 R3 20 G7 8 G3 21 B7 9 B3 22 R8 10 R4 23 G8 11 G4 24 B8 12 B4 25 DIM ALL 13 R5 25CH CHANNE L NAME CHANNE L NAME 1 DIM...

Page 8: ...ED 17 FOREGROUND COLOR 18 BACKGROUND COLOR CHANNEL NAME 1 DIM ALL 2 R 3 G 4 B 5 SHUT 6 AUTO 24CH CHANNEL NAME CHANNEL NAME 1 R1 13 R5 2 G1 14 G5 3 B1 15 B5 4 R2 16 R6 5 G2 17 G6 6 B2 18 B6 7 R3 19 R7...

Page 9: ...G B RG RB GB RGB color snap 11 15 AUTO02 R R G G B B R G R G R B R B G B G B color fade 16 20 AUTO03 B BG BG B G G GR GR G R R RB RB R B Rainbow effect 21 25 AUTO04 each piece change color individuall...

Page 10: ...E3 131 140 SOUND 1 SOUND CHANGE COLOR Sensitivity use menu setting 141 170 SOUND 1 SOUND CHANGE COLOR Sensitivity from low to high 171 180 SOUND 2 SOUND STROBE WHITE COLOR ONLY Sensitivity use menu se...

Page 11: ...ion or parameters decrease Menu Tree TA B LEVEL1 LEVE L2 LEVEL3 LEVEL4 ADDR Address 001 512 STAT Stat ic R 0 255 G 0 255 B 0 255 SHUT 0 255 SET Set CHMD Chan ne l mode 30CH 25CH 25CH 24CH 18C H 12CH 9...

Page 12: ...gram YES NO SEND Send YES NO INFO Informati on SOFT Softw are version Vx x Illustrations When enter to the position displayed on the LED the projector will automatically set as master and send data to...

Page 13: ...enter to the display setting 2 Press the UP DOWN button to select ON 2 MINITES OFF 3 Press the ENTER button to escape and save 6 5AUTO RUN SELF PROGRAM RUNNING 1 Press the ENTER button in AUTO menu t...

Page 14: ...set the others reset to the underlined value of the word 6 8 PROG SELF PROGRAMMING PARAMETER RESET 1 Press the ENTER button in PR L menu then enter to the PROG self programming parameter reset 2 Press...

Page 15: ...3 User manual PROG all will be send for quickly setting same parameters between all fixtures 3 There will be an automatic reset of the other projectors after receiving parameter correctly 8 Infrared k...

Page 16: ...or not Please detect the voltage Power supply is damaged or incorrect connected Call a qualified personnel to fix it Connection of control board is not correct Call a qualified personnel to fix it Out...

Reviews: