HML 210
15
T
T
Start batch from remote input
Start batch from consent (remote)
Start batch from remote input with auto-
batch enabled
POS. 5.10 or POS. 5.11 ENABLED on
batch
POS. 6.1 to 6.4 on end batch
Start batch from remote input with
automatic selection of formula 00/03
N.B.: THE ACTIVATION OF BATCH FUNCTIONS ON INPUT 2
PREVENTS THE ACTIVATION OF BATCH FUNCTIONS ON INPUT 1
Necessary conditions for enabling the function
Necessary conditions for enabling the function
POS. 5.10 ENABLED or POS. 5.11 on
batch
POS. 6.1 to 6.4 on batch
POS. 12.7 ENABLED (Consent mode)
POS. 5.10 or POS. 5.11 ENABLED on
BATCH
POS. 6.1 to 6.4 on END BATCH
POS. 12.5 ENABLED (auto-batch)
POS. 12.7 DISABLED (consent mode)
Necessary conditions for enable the function
T= 100ms ±50ms for select the formula 00
T= 200ms ±50ms for select the formula 01
T= 300ms ±50ms for select the formula 02
T= 400ms ±50ms for select the formula 03
In case of stop batch from remote input the
time of input
POS. 5.10 ENABLED on BATCH or POS.
5.11
POS. 6.1 to 6.4 on END BATCH
POS. 12.6 ENABLED (automatic selection
of formula)
POS. 12.7 DISABLED (consent mode)
POS. 5.11 DISABLED selection function for
the formula 00/01 assigned to input 2 (optional)
Necessary conditions for enabling the function
Start batch from remote input 1 reset p+
enabled on remote input 1
T BETWEEN 1 E 4 = RESET TOTALIZER
T<1 = START E RESET TOTALIZER
Necessary conditions for enabling the function
POS. 5.10 ENABLED (Batch on input 1)
POS. 6.1 - 6.4 on BATCH
POS. 5.2 ENABLED (reset P+)
0-1.5V
3-40V
INP
U
T
O
UT
PUT
Closing
valve
Opening
valve
BATCH
INP
U
T
O
UT
PUT
0-1.5V
3-40V
Opening
valve
Opening
valve
Closing
valve
BATCH
3-40V
0-1.5V
5 Sec.
<5 sec.
INP
U
T
O
UT
PUT
Closing valve
quantity to batch
memorized
Opening
valve
Closing
valve
AUTO-BATCH
BATCH
3-40V
0-1.5V
Formula selection
Start
INP
U
T
O
UT
PUT
Opening
valve
Closing
valve
BATCH
INP
U
T
O
UT
PUT
3-40V
0-1.5V
Start
Opening
valve
Closing
valve
BATCH
Start