Controller operation instruction 

 

. Controller Specification 

Temp. setting range: 0.0 - 60.0 

 

Timer setting range: 0 - 99minutes 59 seconds 

  Display error: 

0.5% 

  Sensor

 PT100 

 

. Instruction of panel 

U P / L i g h t

I l l u n i a t i o n

S e t

D O W N / O p e a t e

Alarm

Refrigeration

Heating 

Stop

8

3 0.0

Tem. testting number

Tem. setting number

8

3 0.0

 

 

. Temperature time operation

 

 
Example: Set temperature to 30 ºC, once reached, 5 hours later, stop the machine (T = 30 ºC. Timer = 5 h) 
1. Click the set button to enter into the setting temp. condition, set the temp. at 30

 using up and down keys.  

2. Click the set button, to enter the timer set condition, 

change the hours from “0” to “5” using up and down keys

once you need to set the minutes, also follow the above step.  
When the timer is set to 

“0”, it is means 

there is no timing function, and the incubator runs continuously. 

When the timer is not set to 

“0”

when the inner chamber temp. reaches the set temp. the timer will initiate, 

when the time ends, the machine will stop. When it stops, the light will turn on, the buzzer will tweet 30 seconds, 
press the down keyboard for 4 seconds, the system will start working again, when the buzzer sounds, please 
click any keyboard to stop the sound. 
3. Illumination: click the illumination button and then it will turn on, click again and it will close. 
 

 

Without timer setting              

 

With timer setting 

 
 

. Inner Chamber Specification setting 

Press the set button for more than 3 seconds, the screen will 

show “LC”

. Modify the number 

to “3” 

using up and 

down keys, click the set button again to access the parameters. By clicking the set button, you can change 
through the parameters in the next table and modify each specification, press the set button for 3 seconds to 
exit the settings, the specification will be saved automatically. If during 30 seconds, no button is pressed, it will 
exit settings automatically and will not keep the specification. 

 

 

Alarm

制冷

Heating

停止

Stop

3 0.0

Tem. testting number

Tem. Setting number

运行时间

时间设定 时间设定

3 00

.

报警

制冷

停止

温度设定值

Refrigeration

Alarm

Heating

Stop

3 0.0

Tem. testting number

Tem. Setting number

3 00

.

Refrigeration

Alarm

制冷

Heating

停止

Stop

3 0.0

Tem. testting number

Tem. Setting number

运行时间

时间设定 时间设定

Refrigeration

Alarm

Heating

Stop

3 0.0

Tem. testting number

Tem. Setting number

Refrigeration

Alarm

05  00

:

Summary of Contents for INCR-070-001

Page 1: ...LBX INC R Refrigerated Incubator Please read the User Manual carefully before use and follow all operating and safety instructions user manual english ...

Page 2: ...ith the following information Serial number Description of the problem Your contact information Warranty This instrument is guaranteed to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the date of invoice The warranty is extended only to the original purchaser It shall not apply to any product or parts which have been damaged on accoun...

Page 3: ...licon 7 50mm diameter test hole Product specifications Model INCR 070 001 INCR 150 001 Voltage 220 240V 50Hz 60Hz Temp Range 0 65 Temp Motion 0 5 Temp Uniformity 1 Cryogen R134a Power 800W 1000W Inner Chamber size cm 35 x 41 5 x 50 40 x 49 x 75 Exterior Size cm 56 x 57 x 103 62 x 64 x 129 Inner Chamber Temp Distribution map 9 7 8 4 1 3 2 6 5 Temperature Graph 30 20 10 0 30 60 10 20 30 40 50 60 30 ...

Page 4: ...you add one working equipment into the chamber if the power is bigger than 2A plug the power outside do not use this equipment power 6 When the chamber temp 50 please do not set the low temp settings to make sure the compressor can be used for a long time 7 Anyone who operates the equipment must first read this manual Operation cautions 1 There is a test hole at the top of the incubator If you add...

Page 5: ... 30 seconds press the down keyboard for 4 seconds the system will start working again when the buzzer sounds please click any keyboard to stop the sound 3 Illumination click the illumination button and then it will turn on click again and it will close Without timer setting With timer setting ⅳ Inner Chamber Specification setting Press the set button for more than 3 seconds the screen will show LC...

Page 6: ...uP and compressor delay time out then compressor begin to work 50 0 50 0 0 2 Dn Cooling refrigeration backlash compressor in manual model when PV SP dn the compressor shut down 51 0 uP 0 1 0 T Control cycle 1 60sec 5 P Proportional band 1 0 measure value 35 I Integration time 1 1000sec 200 d Differential time 1 1000sec 200 Pb 0 adjust Sensor zero display error adjusts Pb actual temp display number...

Page 7: ...n is pressed it will exit settings automatically and will not keep the specification Paramet er Name Function Range factory value Lc Password when Lc 18 we can check the ambient temperature Hd Ambient temp Parameter Parameter Function range Factory value Lc Lc 123 can see and modify each parameter S H When ambient temp SH Temp Setting value the compressor normally open operation On the contrary th...

Page 8: ...en Check the ice or oil block Specification mixed Setting correct and restart Temp up continue Evaporator frost Dry the chamber Abnormal Knocking Circle Fans loose Check and adjust Condenser Fan compressor loose Check and adjust or contact with us Bad evenness degree Sample hot Reduce sample quantity Evaporator frost wind block Dry the chamber Restart Controller instability Power do not match Chan...

Page 9: ... vertederos De conformidad con la Directiva 2002 96 CE los usuarios de la Unión Europea de aparatos eléctricos y electrónicos tienen la oportunidad de retornar el instrumento para su eliminación al distribuidor o fabricante del equipo después de la compra de uno nuevo La eliminación ilegal de aparatos eléctricos y electrónicos es castigada con multa administrativa Les appareils électriques et élec...

Page 10: ...www labbox com ...

Reviews: