background image

4.

2.

1.

The water outlet can't be placed in water in

order to drain smoothly.

The drain hose can't be fluctuant

2.

Step 5: 

Connect outdoor electric wire

wall

U-shaped curve

drain hose

the drain hose

can't raise

upwards.

The water outlet 

can't be placed

in water

The wiring board is for reference only, please refer

to the actual one.

The drain hose

After tighten the screw, pull the power cord slightly

to check if it is firm. 

Never cut the power connection wire to prolong or

shorten the distance.

can't be fluctuant

The water 

outlet can't be

fluctuant

Step 6: 

Neaten the pipes

Remove the wire clip; connect the power con-

nection wire and signal control wire (only for

cooling and heating unit) to the wiring terminal

according to the color; fix them with screws.

9

Fix the power connection wire and signal con-

trol wire with wire clip (only for cooling and h-

eating unit).

1.

Slant the drain hose slightly downwards. 

The drain hose can't be curved, raised and 

fluctuant, etc.

The through-wal  height of drain hose shoul

not be higher than the outlet pipe hole of in-      

door unit. 

Tighten the union nu t with torque wrench

by referring to the sheet below.

15~20

30~40

45~55

60~65

70~75

1/4''

3/8''

1/2''

5/8''

3/4''

NOTICE

NOTICE

Hex nut diameter

Tightening torque(N  m)

.

NOTICE

 reasonably and hidden possibly. Min. semidiam-

 eter of bending the pipe is 10cm.

The pipes should be placed along the wall, bent

L1

L2

black

Indoor unit connection

black(brown)

green

(yellow-green)

white(blue)

L2
L1

green(yellow-green)

POWER

white

(blue)

red

(brown)

N(1)

2

3

09K

 

12K

N

L

black

Indoor unit connection

black(brown)

green

If the outdoor unit is higher than the wall hole,

you must set a U-shaped curve in the pipe

before pipe goes into the  room, in order to

prevent rain from getting into the room.

(yellow-green)

white(blue)

L
N

green(yellow-green)

POWER

white

(blue)

red

(brown)

3

)

1

(

N

2

09K

 

12K

For some models

 

white

  black red

L1 L2

Indoor unit connection

POWER

(blue)

(brown)

white

(blue)

N(1)

2

3

black

(brown)

L1 L2

green

green)

(yellow-

green

green)

(yellow-

18K

24K

Summary of Contents for LBH09AWO

Page 1: ......

Page 2: ......

Page 3: ...LBH09AWO LBH12AWO LBH09DWO...

Page 4: ......

Page 5: ...CONTENTS Safety precautions 01 05 06 08 10 11 Parts name Installation notice Installation of outdoor unit Test and operation Configuration of connection pipe...

Page 6: ...reasons This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information u...

Page 7: ...ir conditioner Unstable power supply or incorrect wiring may result in electric shock fire haza rd or malfunction Please install proper power supply cables before using the air conditioner The groundi...

Page 8: ...must be po sitioned so that the plug is accessible For the air conditioner with plug the plug should be re achable after finishing in stallation For the air conditioner with out plug a circuit breaker...

Page 9: ...by the manufacturer its ser vice agent or similarly qua lified persons in order to avoid a hazard Do not connect air condi tioner to multi purpose soc ket Otherwise it may cau se fire hazard Do discon...

Page 10: ...It may cause mal function Do not step on top panel of outdoor unit or put heavy objects It may cause dam age or personal injury When below phenomenon occurs please turn off air conditioner and discon...

Page 11: ...5 Parts name Outdoor Unit Actual product may be different from above graphics please refer to actual product air inlet air outlet NOTE...

Page 12: ...stances other than the specified refrigerant Any presence of air or other foreign substance in the refrigerant circuit will cause system pre ssure rise or compressor rupture resulting in injury Measur...

Page 13: ...unction Pl ease install proper power supply cables before using the air conditioner 5 Be sure to cut off the power supply before pr oceeding any work related to electricity and safety Outdoor unit 1 S...

Page 14: ...n 20cm For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacit...

Page 15: ...nwards The drain hose can t be curved raised and fluctuant etc The through wal height of drain hose shoul not be higher than the outlet pipe hole of in door unit Tighten the union nut with torque wren...

Page 16: ...ent approves the air conditioner Specify the important notes for air conditioner to the client Items to be checked Possible malfunction The unit may drop shake or emit noise Has the unit been installe...

Page 17: ...e The calculation method of additional refrigerant charging amount on the basis of liquid pipe Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging am...

Page 18: ...B WB C F 26 7 19 4 80 67 50 24 122 75 Outdoor side NOTICE Maximum heating 30 18 86 65 Outer diameter mm LBH09AWO LBH12AWO ature for cooling is 25 C 13 F 50 C 122 F for heating is 30 C 22 F 30 C 86 F 6...

Page 19: ......

Page 20: ...66129937352...

Reviews: