Global Alarm
The global alarm can be output by both the
GLOBAL ALARM
The global alarm status can also be monitored from the
Global alarm errors are stored on the control system in the
alarm.log
system
The global alarm can be disabled by the AdminHD configuration (see
Parameters: Core -> System Settings
).
When enabled, the global alarm is triggered when any of the following conditions are satisfied:
Within the Nova73:
·
Malfunction of a Router module.
·
High temperature on a Router module – triggered if the temperature exceeds 45° C.
·
Too high or too low a voltage to a Router module.
·
Malfunction of an I/O module in the Nova73.
·
Malfunction of a PSU.
·
Malfunction of a fan.
·
Active external control input – the global alarm can be triggered by a control input from an external device
(e.g. via GPI).
·
Internal sync (optional) - the global alarm can be triggerd if the system switches to internal sync (see
).
From an I/O Port (e.g. DALLIS or external device):
·
If the port is not supplied with a valid signal.
·
Malfunction of a DALLIS master board.
·
Malfunction of a DALLIS I/O card.
·
Malfunction of a DALLIS PSU.