Chapter 3: AdminHD
Core Configuration: First Steps
Uploading Data to the Online Configuration
For temporary changes to the Core configuration, or for installations where a cold start is not possible, you should
upload your data to the online configuration. This updates the online system without requiring a restart and can be
useful for testing, or updating systems where a cold start is not possible (for example, if 24 hour continuous
operation is required).
The online configuration is stored in the system's
data (at shutdown), and recalled following a normal
restart (warm start). Providing you do not
the system, any changes made will remain intact.
Only the
Core configuration
can be modified in this manner (you cannot update the
Signal List
or
Console Configuration
).
Warm start data is temporary. Therefore, this method is
NOT
recommended for permanent changes to the
configuration. If the control system is 'cold started', then it reads the
config.tcl
file, and any changes to the
online configuration will be reset.
To upload your current AdminHD session to the online configuration:
1.
Enable
mode, by clicking on
from the main
Online to remote system
).
AdminHD now connects to the remote system and compares the online configuration to the one open in
AdminHD. When the analysis is complete, an 'Upload summary' appears:
This list allows you to review the changes which you are about to make
BEFORE
you continue with the upload.
2.
Read through the list and click on
Upload
to continue (or
Cancel
to abort the upload).
The
shows the progress of the upload; after a successful upload, the system immediately updates.
Summary of Contents for mc256 MKII
Page 1: ...Technical Manual mc 56 MKII Version 5 10 2 1 Edition 12 September 2017...
Page 350: ...mc 56 MKII Technical Manual V5 10 2 1 350 Chapter 7 Appendices Local I O Wiring...
Page 351: ...mc 56 MKII Technical Manual V5 10 2 1 351 Chapter 7 Appendices Local I O Wiring...
Page 352: ...mc 56 MKII Technical Manual V5 10 2 1 352 Chapter 7 Appendices Local I O Wiring...