background image

Clearing Errors

You can correct a mistake while setting hours, minutes or
watering days, press Clear/Rain to return to the original
setting, then enter in the correct information.
The controller will not accept a run time greater than 12
hours, 59 minutes. Instead, it will respond by flashing

     

 on the display for 30 seconds. During this time

you must press 

 and enter the correct run time, or

the controller will revert to the previous run time settings.

Reviewing your programmed schedule

You can review any start time or Zone data-even while
watering. Cycle through the settings for either function by
repeatedly pressing either 

 or 

 If no key is

pressed for 30 seconds, the display returns to the con-
trollers current operating mode.

Manual watering

You can manually water all Zones or a selected Zone at
any time-except when an automatic watering cycle is
already in progress.
To water all Zones (except Zones set to OFF), press 
twice. Each Zone will water in numerical sequence for

its programmed run time.

To water a selected Zone, press MAN once. Then press

 repeatedly to display the desired Zone. Press 

again to start watering the Zone displayed.
To water a selected Zone for a specific amount of
time, 
press MAN once. Then  

 repeatedly to

display the desired Zone. Next, press 

 and enter

the new run time using the numbered keys. Finally,

press 

 once more to start watering this Zone.

Changing run times in manual mode won’t alter your
original program settings.

Interrupting the watering cycle

You can stop a watering cycle already in progress by
pressing 

 once (PAUSE and RUN TIME messages

will flash). Press 

 again to resume watering. If left in

pause mode until midnight, controller will automatically
reset to begin watering at the first programmed start time
of the new day.

Turning off the system/rain shut-off

You can prevent automatic watering from starting by
pressing 

 when no watering is taking place.   A 

 

will flash on the display. Press 

 again to resume

watering.

Pushing 

 when automatic watering is already in

progress will terminate the watering then taking place,
but resume automatic watering at the next start time.

You may still activate manual watering when controller is

in rain mode.

Changing programmed settings

You can enter new program settings for time and day,
start times, and Zones at any time-even while water-

ing is taking place. However if you alter run time or

watering days on a Zone that is currently operating, the
change will not effect the watering then in progress; all
changes take effect with the next watering cycle.

Likewise, changing start time, clock time, or clock day

will not effect watering already in progress.

16

17

Summary of Contents for L80306P

Page 1: ...Genie Multiple Program Electronic Controller Installation and Operation Guide b For Model L80306P b Please read instructions completely before attempting to install or operate controller m _____ H La...

Page 2: ...e livered to different parts of your yard by assigning a dif ferent day schedule and run time to one or more sprink ler heads controlled by a single valve Each valve and the sprinklers it controls are...

Page 3: ...to allow for programming and reviewing schedules Clear Rain key For stopping automatic watering in progress preventing automatic watering from starting or clearing entry errors Pause key For temporari...

Page 4: ...de this wire in 2 3 4 5 6 7 and 8 wire color coded strands B Connect a single common wire to one of the wires from each valve NOTE It doesn t matter which of the two valve wires you use C Solder or jo...

Page 5: ...that wiring and installation meet all requirements In the controllers display P represents noon and I z R represents midnight When the power is first turned on the controller always displays it It fi...

Page 6: ...il properly programmed To program a Zone to water at specific day intervals A Press ZONE 1 is displayed with a run time of n 5 B Press The run time begins to flash C Press the appropriate numbered key...

Page 7: ...ntered and START NO 2 is indicated with I r F F displayed E Repeat steps B C and D to set additional start times IMPORTANT Program any unused start times to OFF For each press followed by and Since al...

Page 8: ...your sprink ler controller can activate the valve or pump A Bring two wires up through the same hole in the controller cabinet used for the valve wiring B Connect one wire to the terminal marked PUMP...

Page 9: ...repeatedly to display the desired Zone Next press and enter the new run time using the numbered keys Finally press once more to start watering this Zone Changing run times in manual mode won t alter y...

Page 10: ...ne or more valves do not water F I_ 5 and a Zone number are alternately flashing on display Clock won t keep correct time and or controller won t retain programming Zones turn on when they re NOT prog...

Page 11: ...al or reinstallation of any so called defective products NO IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO FITNESS FOR A PARTICULAR PURPOSE WHERE APPLICABLE AND MERCHANTABILITY SHALL EXTEND BEYOND TH...

Page 12: ...Zone Watering Days Run Time location I 6 Start Times 1 A 1 B I 2 A I 2 B I q Hardie Irrigation A James Htrdte Company 21 559001 Rev 10 92...

Reviews: