g024078
Figure 24
5.
After draining the used oil, return the machine to
the operating position.
6.
Carefully pour about 3/4 of the engine capacity
of oil into the oil-fill tube.
7.
Wait 3 minutes for the oil to settle in the engine.
8.
Wipe the dipstick clean with a clean cloth.
9.
Insert the dipstick into the oil-fill tube, screw it in,
then remove the dipstick.
10.
Read the oil level on the dipstick (
).
•
If the oil level on the dipstick is too low,
carefully pour a small amount of oil into the
oil-fill tube, wait 3 minutes, and repeat steps
through
until the oil level on the dipstick
is correct.
•
If the oil level on the dipstick is too high,
drain the excess oil until the oil level on the
dipstick is correct.
Important:
If the oil level in the engine is too
low or too high and you run the engine, you
may damage the engine.
11.
Install the dipstick into the oil-fill tube securely.
12.
Recycle the used oil properly.
Charging the Battery
Electric-Start Model Only
Service Interval:
Every 25 hours
Charge the battery for 24 hours initially, then monthly
(every 25 starts) or as needed. Always use the
charger in a sheltered area and charge the battery at
room temperature (22°C or 70°F) whenever possible.
1.
Connect the charger to the wire harness located
below the ignition key (
g002889
Figure 25
2.
Plug the charger into a wall outlet.
Note:
When the battery no longer holds a
charge, recycle or dispose of the lead-acid
battery according to local codes.
Note:
Your battery charger may have a 2-color LED
display that indicates the following states of charging:
•
A red light indicates that the charger is charging
the battery.
•
A green light indicates that the charger is fully
charged or the charger is disconnected from the
battery.
•
A flashing light that alternates between red and
green indicates that the battery is nearly fully
charged. This state lasts only a few minutes until
the battery is fully charged.
Replacing the Fuse
Electric-Start Model Only
If the battery does not charge or the engine does not
run with the electric starter, the fuse may be blown.
Replace it with a 40 A plug-in type fuse.
Important:
You cannot start the machine with the
electric starter or charge the battery unless you
install the fuse.
1.
Unclip the battery cover and remove it (
20