background image

temperedwater.com

5330 East 25th St.

Indianapolis, IN 46218
Phone (317) 261-1212

Fax (317) 261-1208

INSTALLATION &

MAINTENANCE MANUAL

Design and specifications subject to change without notice.

Please refer to 

temperedwater.com

 to ensure most

current data sheet and other design solutions. 

CAUTION: When maintaining and adjusting the 

mixing valve, all fixtures should be isolated from 

use. Lawler Manufacturing Co., Inc. recommends 

that you work safely at all times and in a manner 

consistent with the OSHA Lock/Tagout standard,  

29 CFR 1910.147 and other applicable standards.

temperedwater.com/patents

M 310 C

ASSE 1070 Approved
ASSE Lead Free Certified

Certified to CSA B125.3

NOTICE!

 

No mixing valve will work satisfactorily if improperly installed. We suggest, therefore, that you read 

these instructions carefully before installing and follow directions as outlined. Handle the mixing valve with care.

CAPACITIES – MODEL 310

 Pressure Drop PSI 

10 

20 

30 

45

  Valve Number 

 

 

Capacity

 

310-1/2” GPM

  1.5 2.5  3.5  5.5  7

 

310-1/2” LPM

 

5.7  9.5  13.3  20.8 26.5

 

310-3/4” GPM

  3.5 5.5  8  10  12

 

310-3/4” LPM

 

13.3 20.8  30  38  45

Model 310

Thermostatic Mixing Valve

DIMENSIONS

  Valve Number 

C

 

310

 

7” 4” 5”

Dimensions are for reference purposes only. For rough-in dimensions 
please refer to Lawler’s Revit/BIM models found at temperedwater.com.

Inlets are 1/2” NPT, outlet may be 1/2” or 3/4” NPT.

72046_310-50_STD_DRW_NODIMS.pdf

B

C

A

This installation & maintenance manual covers all 

configurations of the Model 310.

Summary of Contents for 310

Page 1: ...rtified Certified to CSA B125 3 NOTICE No mixing valve will work satisfactorily if improperly installed We suggest therefore that you read these instructions carefully before installing and follow directions as outlined Handle the mixing valve with care CAPACITIES MODEL 310 Pressure Drop PSI 5 10 20 30 45 Valve Number Capacity 310 1 2 GPM 1 5 2 5 3 5 5 5 7 310 1 2 LPM 5 7 9 5 13 3 20 8 26 5 310 3 ...

Page 2: ...t should be installed CAUTION Extreme care should be exercised when placing thermostat in and out of hot water Mixing valve Valve is carefully assembled and tested at the factory and set to deliver water at any temperature between full cold and 115 F Failure of the cold water supply will cause the hot water seat to close The label on the valve cover is marked WARMER COOLER so that the temperature ...

Page 3: ...the operation of the mixing valve When in Need of Information When writing the factory or one of its representatives in regard to a mixing valve be sure to give the valve number and serial number appearing on round label plate fastened to the top of the valve Repair Kit Valves can be completely rebuilt in a matter of minutes without removal from the line by installing a repair kit WARNING This pro...

Page 4: ...0 26 78271 03 D Thermostat Assembly 10 19 71870 21 Must specify capacity and finish of valve Parts shown under 1 2 are for 1 5 GPM All parts shown are for Plain Bronze finish For complete repair kit order universal kit 79850 00 Repair Kits and Assemblies Repair Kits for Inlet Stop Checks NOTE Components are not included in repair kit Item Description 1 Bonnet 2 Packer 3 Washer 4 Stem 5 Spring 6 No...

Reviews: