18
maintenance
WARNING
• Never service heater while it is plugged in or while hot!
Maintenance
FUEL TANK
AIR FILTERS
Use only original equipment replacement parts. The use of alternate or
third party components can cause unsafe operating conditions, and will
void your warranty.
We suggest following a maintenance schedule as follows:
Flush every 200 hours of operation or as needed. Do not use water to
flush the tank. Use fresh 1-K kerosene only.
The Air Intake Filter should be replaced or washed with soap and water
and dried thoroughly every 500 hours of operation, or less, depending on
conditions.
The Output and Lint Filters should be replaced every 500 hours of opera-
tion or less, depending on conditions.
NOTE:
Use of diesel may require additional maintenance.
HK175FH_LavorPro Heater_Manual_2016.indd 18
2016-04-01 11:39 AM
Summary of Contents for HK175FH
Page 2: ...2 HK175FH_LavorPro Heater_Manual_2016 indd 2 2016 04 01 11 39 AM...
Page 23: ...23 PARTS BREAKDOWN diagrams HK175FH_LavorPro Heater_Manual_2016 indd 23 2016 04 01 11 39 AM...
Page 27: ...27 HK175FH_LavorPro Heater_Manual_2016 indd 27 2016 04 01 11 39 AM...
Page 28: ...28 HK175FH_LavorPro Heater_Manual_2016 indd 28 2016 04 01 11 39 AM...