Oil Fired Radiant Heater User’s Manual
NEVER LEAVE HEATER UNATTENDED WHILE
BURNING, CONNECTED TO A POWER SOURCE
OR WHILE CONNECTED TO A FUEL SOURCE.
© 2013, BE Pressure Supply Pty Ltd
Kerosene Forced Air Heater User’s Manual
NEVER LEAVE HEATER UNATTENDED
WHILE BURNING, CONNECTED TO A
POWER SOURCE OR WHILE
CONNECTED TO A FUEL SOURCE.
2SHUDWLRQ
6WDUHDWHU,JQLWLRQ
1. Fill the tank with kerosene or other approved
fuel until needle on fuel gauge points to “F”.
2. Replace fuel cap and tighten firmly.
Connect the heater to a three prong
(grounded) power source. You must use a
three prong (grounded) extension cord that is
at least 1.8 meters long and is a minimum of
14 AWG rating.
4. Turn thermostat control knob to desired
temperature setting. The thermostat set range
LVIURP&WR&
5. Move power switch to “On” position. The
power indicator light and room temperature
display will illuminate and heater will ignite.
(See Figure 10)
127(,ILIWKHKHDWHUVWLOOGRHVQRWLJQLWHUHIHUWR
³7URXEOHVKRRWLQJ*XLGH´RQSDJH
127(7KH+.)$GRHVQRWKDYH
DURRPWHPSHUDWXUHGLVSOD\IHDWXUH
The room temperature display will indicate the
following:
- When the temperature is less than -17.8 ºC the
display says “LO”.
:KHQWKHWHPSHUDWXUHLVPRUHWKDW&WKH
display says “HI”.
- Between -17.8
°
&DQG
°
C the display shows
actual temperature.
6WRSSLQJ5HVHDWHU
- To stop the heater, move the power switch to the
“Off” position and unplug the power cord.
- To restart the heater; wait 10 seconds and follow
ignition steps.
Figure 9
Power Switch
Power Switch
Thermostat Knob
Temperature Display
Figure 10
8
TIP: If the heater does not ignite, the
thermostat may be set too low. Turn
the control knob to a higher setting until the
heater ignites. If the heater does not ignite;
move switch to “Off” position, check steps 1-3
above and then move switch to “On” position.