EN
15
lem repeats again or if the product does not
start again, take the product to the nearest
After Sales Service Point
> STABILITY
WARNING:
The machine must be always kept
on horizontal bases, in a safe and stable way.
USAGE
>
DESCRIPTION OF THE MACHINE
See the specific instructions manual provided.
>
ASSEMBLY INSTRUCTIONS
See the specific instructions manual provided.
>
PUT INTO SERVICE
See
fig.
>
STARTING UP
See
fig.
>
HIGH PRESSURE LANCE
See
fig.
>
DETERGENT SUCTION
See
fig.
>
HIGH PRESSURE HOSE
See
fig.
>
WATER SUPPLY
Water supply collection
Water supply from the water main
· Connect a supply hose (not included) to the
water inlet of the unit and to the water supply.
· Open the water supply.
WARNING:
(symbol) machine not suitable
for connection to the potable water mains.
The cleaner can only be connected to the wa-
ter mains if the water mains is separated by a
backflow preventer. Make sure that the hose
is at least Ø 13mm-1/2 inch and that it is rein-
forced.
WARNING:
Water that has flown through
backflow preventers is considered to be
nonpotable.
IMPORTANT:
Only clean or filtered water
should be used for intake. The delivery of the
water intake tap should be equal to the double
of the maximum pump range.
- Minimum delivery rate: 15 l/ min.
- Maximum intake water temperature: 40°C
- Max inlet water pressure: 1Mpa
Place the cleaner as close to the water supply
system as possible.
Water supply from an open container
· Unscrew the coupling part for the water inlet.
· Screw the suction hose with filter (not included)
onto the water connection of the unit.
· Hang the filter in the container.
· Vent the unit before operation.
· Unscrew the high-pressure line at the high-
pressure outlet of the unit.
· Switch on the unit and let it run until water
free of bubbles emerges at the high-pressure
outlet.
· Switch off the unit and screw on the high-
pressure hose again.
Failure to comply with the above conditions
causes serious mechanical damage to the
pump and the loss of warranty cover.
>
ELECTRICITY SUPPLY
- The appliance’s electrical connection must
comply with the IEC 60364-1 standard.
IMPORTANT:
Before connecting the
appliance, make sure that the nameplate data
are the same as those of the electrical mains
and that the socket is protected by a differential
security breaker with tripping sensitivity below
0.03 A - 30 ms.
- If the appliance’s plug is not compatible with
the socket, have the socket replaced with
another of suitable type by professionally
qualified staff.
-
Never use the appliance in ambient
temperatures below 0° C if it is equipped with a
PVC (H VV-F) cable.
XY WARNING:
Inadequate extension cords
can be dangerous.
XJ WARNING:
If an extension cord is used,
the plug and socket must be of watertight
construction.
Information for supply may also be obtained