SET CO2 PRESSURE
1. Set the CO2 regulator to 50 psi or (3.5 Bar)
2. Align the arrow to the beginning of the wide RED bar on the knob
3. Once CO2 is turned on, CO2 Cylinder Icon will change from red to black
4. Purge air from the system from the rear purge valve. (3) one second
pulses
NOTE: IT TAKES APPROXIMATELY TWO HOURS FOR THE SYSTEM TO CHILL
DOWN TO THE PROPER TEMPRETURE
SET UP DATE AND TIME
1. Select the gear icon from the home screen
2. Set the date and time
3. Hit the back arrow to return to the main
screen
BLEED AIR FROM LINES
1. Press the Lavit button to clear the still water line
2. Select Water Only – Medium Soda Water to clear
the soda water line
CALIBRATION
Proper Beverage Volume is critical to create great
tasting beverages.
1.Select the Gear icon
2. Select Service Set Up shown above in Set date
picture
3. Enter Password 8888 – Enter to display the
SERVICE MENU
4. on next screen Select Water Set Up
CALIBRATION continued
There are three water streams in a Lavit Cooler:
1. Still Water–pumped from cold tank
2. Mix Stream– Using an ECO Cap start mix stream for 2-
second then stop. Dump water from your measuring then
start mix stream calibration again stopping it at 12OZ. The Mix
stream uses external inlet water to create the beverage
mixture
3. Soda Water – from soda tank using CO2 pressure
Calibrate the three water streams: Still, Mix and Soda.
1. Using a measuring cup press “Start” to begin flow and
“Stop” to end flow when 12 ounces is dispensed
2. Do this for each stream
3. After calibration, verify 12oz volume by creating a new
Still and Carbonated Beverage
7