WARNING:
1.
Turn off the engine and wait for the fan impeller to completely stop before opening the
machine to change filters.
2.
Do not touch the exhaust as it will get very hot even after running the engine for a short
period of time.
IMPORTANT:
All of the following procedures must be performed with the dust collector turned off
(look at the beginning of chapter 7). Before performing any work or maintenance on the vacuum, be
sure to wear the proper protective equipment. This might include clothing which covers any exposed
skin, protective eyewear, a respirator, and/or protective gloves conforming to protection class FFP3.
IMPORTANT:
the used filer and debris must be disposed of using methods which fully comply with
local environmental laws and regulations.
To change the HEPA filter you need to follow the four steps as it’s shown in fig. 7.4.
1
st
Release the four latches (fig. 7.4.1).
2
nd
Remove the HEPA chamber’s top and make sure that the sealing rings are in place (fig. 7.4.2).
3
rd
Lift out the HEPA filter and place it carefully in a plastic bag (fig. 7.4.3).
4
th
Before you insert the new HEPA filter check the sealing on the chamber’s bottom (fig. 7.4.4).