Warning
Before putting the thermoblock
back into its housing, the
GASKETS indicated in figure C
must be replaced.
Take care to remove any residual thermal grease in the contact point (1) of the THERMOBLOCK PROBE and
apply fresh grease before setting the PROBE back in place.
Figure D
: remove the THER-
MOBLOCK CONNECTION (
2
) in
the dispensing unit by extracting
the retaining fork (
3
), removing
the hydraulic connection (
4
) and
unscrewing the THERMOBLOCK
CONNECTION by rotating it anti-
clockwise.
Warning
If the THERMOBLOCK
CONNECTION is to be replaced,
also replace the O-RING
11X1.9 (5) and if necessary,
the RUBBER CAP (6) within, as
shown in figure E.
C
1
E
D
2
3
4
G
E
5
6
Summary of Contents for blue LB 400 CLASSY PLUS