background image

LAVA Computer MFG. Inc.                                                                                        STS-RBM Installation Manual 

– A03 

 
 

  2 Vulcan St. Toronto, ON        Tel:  +1 416 674-5942         www.lavalink.com

                                

5 of 8 

  Canada, M9W 1L2                   Fax: +1 416 674-8262         Toll-Free (US & Canada): 800 241-5282

 

 

  

Preparation of the STS-RBM Board 

The TYPE Headers determine the type of Samsung tablet to be connected to. It is 

critical 

to set these 

headers with the correct jumpers else the tablet may not charge very well or may not charge at all. Each of 
these headers has two pins and uses a standard 0.1- inch jumper. 
 

TYPE Header Jumper Options 

Header  1 

Header 2 

Description 

Open 

Open 

Operation with Tab E, Tab S2, Tab A 

Installed 

Open 

Operation with Tab 4 

Open 

Installed 

Reserved for future use 

Installed 

Installed 

Force Boot Loader to run. 

 

Connecting STS-RBM to the Tablet 

Connect the STS-RBM to the tablet using the LAVA provided cable. This cable has a Micro USB-B 
connector at each end. This cable must not be extended. 
 
Plug one end of the LAVA cable to the Micro USB-B Port on the board. Either end of the cable can be 
used. Always verify the connector orientation to prevent damaging the receptacle. 
 
Plug the other end of the LAVA cable to the tablet. Always verify the connector orientation to prevent 
damaging the receptacle. 
 

Powering up the STS-RBM (PoE) 

Attach an RJ45 Cat-5 cable between the STS-RBM and a PoE Enabled Network Switch. The alternative is 
to use a PoE Power Injector and a non-PoE Network Switch. 
 

Warning:

 When using a Network Switch Port that is providing power, the 5 Volt input must not be used. 

 

Powering up the STS-RBM (5V USB Supply) 

If not using PoE to supply power to the STS-RBM, then a 5V USB Supply can be used. 
 
Attach the power cable from a 5V USB Power supply to the 5V Input Port of the STS-RBM. 
 
The Power Supply provided with the Samsung tablet is an ideal choice. Do not extend the original power 
supply cable until the system has been debugged. Ensure the supply is rated for at least 2 amperes. 
 
The voltage reaching the STS-RBM should be at least 5 volts. The preferred range is 5.1 to 5.25 volts. The 
input voltage must never exceed 5.25 volts. Exceeding 5.25 volts can result in immediate system damage.  
 

Warning: 

When supplying power using the 5 Volt input, you must not 
 use a Network Switch Port that is providing PoE power. 

Summary of Contents for STS-RBM

Page 1: ...t and improved network operation This document describes the STS RBM setup and software installation procedure for the tablet Contents Introduction 2 LAVA STS RBM Software Release Package 3 Product Setup 4 Installation of LAVA Software 4 Preparation of the STS RBM Board 5 Connecting STS RBM to the Tablet 5 Powering up the STS RBM PoE 5 Powering up the STS RBM 5V USB Supply 5 Power Up Behavior 6 Ad...

Page 2: ...application as a Device Administrator and activate the KNOX license Disable the WiFi connection optional Turn off the auto screen brightness on the Tablet Verify the time zone and time on the Tablet Verify the TYPE jumpers on the STS RBM are set for your tablet model Connect the STS RBM Product to the Tablet with the supplied LAVA cable Apply power to the STS RBM Product Do not plug in USB accesso...

Page 3: ...fy the battery charge status Installation of this application is recommended for initial verification of the STS RBM This application can be removed once the STS RBM is operational This application is also available on Google Play as the LAVA Advanced Battery Information 5 LAVA Battery Information Manual PDF The manual for the LAVA Battery Information application The source code for the LSR APK ca...

Page 4: ...ce Administrator Locate the Device administrators menu On newer Tablets the required menu is under the Lock screen and security Other security settings On older Tablets the required menu is under General Security Enable LAVA Tablet Manager VII in the Device Administrator menu and then select ACTIVATE After selecting activate the next menu presented is for accepting a Samsung KNOX license If you pr...

Page 5: ...erify the connector orientation to prevent damaging the receptacle Plug the other end of the LAVA cable to the tablet Always verify the connector orientation to prevent damaging the receptacle Powering up the STS RBM PoE Attach an RJ45 Cat 5 cable between the STS RBM and a PoE Enabled Network Switch The alternative is to use a PoE Power Injector and a non PoE Network Switch Warning When using a Ne...

Page 6: ...file If the STS RBM is placed into the Charge Only mode using the Charge Mode button the LTM Service shuts down and all USB devices are disconnected Additional Comments With LTM running the battery level is maintained between the upper and lower thresholds defined in the LTM INI file The LAVA Battery Information LBI application can be used to monitor the battery charge status When the charging sta...

Page 7: ...m 7 of 8 Canada M9W 1L2 Fax 1 416 674 8262 Toll Free US Canada 800 241 5282 STS RBM Board Board Layout This document presents the basic information for the STS RBM board layout Please consult the STS RBM Reference Manual for a detailed description of the board connectors buttons and options STS RBM L181 1 Board ...

Page 8: ...00 241 5282 Internet www lavalink com helpdesk History Document Revision Date Change A00 Oct 02 2016 Initial release A01 Nov 01 2016 Revised the software installation steps Revised the Power Up Behavior section A02 May 16 2017 Revised the document to follow layout of the eSTS Installation Manual A03 Sep 27 2017 Added effect of a Mobile Device Management application during LTM installation Removed ...