4. Unscrew and remove the metal slot cover corresponding to the slot

that will hold the FireHost card, and retain the screw.

5. Holding the FireHost card without touching its gold connectors,

insert it into the PCI slot. Ensure that it is well seated.

6. Screw the metal bracket of the FireHost card to your PC’s casing and

replace the machine’s cover.

7. Reattach all peripherals to your computer, and start the system.

Summary of Contents for FireHost

Page 1: ...Lava FireHost Installation Manual Rev B00 LAVA COMPUTERS 1394_PCI FIREHOST P N MOKO L88 0 MADE IN CANADA ...

Page 2: ...r computer according to the manufacturer s instructions Before proceeding further touch a bare metal portion of the computer case to discharge any static electricity your body may have 3 Locate an unused PCI slot any PCI slot will do PCI slots are white plastic PCI Slot Screw for attaching card bracket to PC casing Ports ...

Page 3: ...d retain the screw 5 Holding the FireHost card without touching its gold connectors insert it into the PCI slot Ensure that it is well seated 6 Screw the metal bracket of the FireHost card to your PC s casing and replace the machine s cover 7 Reattach all peripherals to your computer and start the system ...

Page 4: ...s it will detect the new FireHost PCI host adapter in your system and display the first screen of the Add New Hardware Wizard shown below Click on Next 2 In the next screen of the Add New Hardware Wizard select Display a list of all the drivers then click Next ...

Page 5: ...ck on Show all hardware Windows will display a list of manufacturers and models from which you can select the Texas Instruments OCHI Compliant IEEE 1394 Host Controller device driver After selecting this driver click Yes on the update warning prompt that appears 4 Windows will now either confirm that it has found the driver file you specified or prompt you to insert your Windows installation CD Cl...

Page 6: ...log box Click Finish to complete installing the FireHost adapter To check that the FireHost was correctly installed go to My Computer Control Panel System Device Manager and click on the plus sign in front of the 1394 Bus Controller heading You should see an entry for the Texas Instruments OHCI Compliant IEEE 1394 Host Controller ...

Page 7: ...lot and insert the FireHost Adapter into it Ensure that it is well seated Close the case 3 Turn the Mac on When an operating system starts it will automatically find the FireHost Adapter 4 To check if the FireHost was properly installed go to Apple Menu Apple System Profiler 5 Select the Devices and Volumes tab and check for the FireHost ...

Page 8: ...et www lavalink com This device complies with part 15 of the FCC Rules Operation is subject to the following conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Lava Computer MFG Inc 908 Niagara Falls Blvd 629 North Tonawanda NY 14120 2060 ...

Reviews: