background image

For sales inquiries, contact Sylvane at 1-800-934-9194.
If you have service questions, contact Lava Heat at 1-888-779-5282.

Summary of Contents for SRPH30-XXXX ALTO

Page 1: ...For sales inquiries contact Sylvane at 1 800 934 9194 If you have service questions contact Lava Heat at 1 888 779 5282 ...

Page 2: ...y of this or any other appliance DANGER WARNING WARNING For Outdoor Use Only CAUTION Installer Leave the instruction manual with the user for future use Consumer Please keep this manual for future reference Read the instructions before use This appliance must be installed in accordance with such regulations as are in force An LP cylinder not connected for use shall not be stored in the vicinity of...

Page 3: ...e can cause injury death or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment SPECIFICATION Certification CSA Height Overall Reflector Diameter Rated Heat Input l e u F Gas Supply 20Lb 9kg LP Gas cylinder Manifold Pressure 11 0 W C Injector Size diameter 1 95mm Safety Features Flame failure device anti tilt switch ...

Page 4: ...or in areas where the hose will not be subject to accidental damage Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required as necessary ...

Page 5: ...d must not be stored in a build ing garage or any other enclosed area The pressure regulator and hose assembly sup plied with the appliance must be used replace ment pressure regulators and hose assemblies must be those specified by the appliance manu facturer The hose assembly must be replaced prior to the appliance being put into operation if there is evidence of excessive abrasion or wear or if...

Page 6: ...r Estimated time for assembly 30 minutes Before beginning assembly of product make sure all parts are present If any part is missing or damaged do not attempt to assemble the product Contact customer service for replacement parts Perform a leak test with a soapy solution 1 To check gas connections 2 After connecting a new cylinder 3 Upon re assembly after disassembly TOOLS NEEDED NOT INCLUDED 5 ...

Page 7: ...4 Bolts 3 M6 Nuts 6 6mm Washers 3 M6x70 Double Pointed Bolts 5 M4x8 Bolts 6 M5x12 Bolts 1 Reflector 1 Burner Assembly 1 Upper Pole 1 Lower Pole 1 Desk surface 1 Pole supporting board 1 Cylinder Chain 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 8 9 1 10 2 11 12 3 13 4 5 14 15 16 7 6 ...

Page 8: ...SSEMBLY 15 14 16 Hardware Used Hardware Used 5mm washer X 6 M5 X 12 bolt X 6 M6 X 14 bolt X 4 Step 1 Step 2 Insert lower pole 4 into the pole supporting board 6 fix it with 6 pcs 5mm washers 14 and 6 pcs M5x12 bolts 15 Put the desk surface 5 in the lower pole 4 fix it with 4 pcs M6 14 bolts 16 4 6 15 14 16 5 4 ...

Page 9: ...ware Used 4mm washer X 5 M4 X 8 bolt X 5 Step 3 Step 4 Step 4 Connect the upper pole 3 on the lower pole 4 fix it with 6pcs M5x12 bolts 13 Insert the burner assembly 2 in the upper pole 3 fix it with 5pcs 4mm washers 11 and 5pcs M4 8 bolts 12 3 4 13 3 2 12 11 ...

Page 10: ...inted Bolts x 3 6mm Washer x 6 Step 5 Step 5 Install reflector assembly 1 fix it with 3pcs M6 70 double pointed bolts 10 6pcs 6mm washers 9 and 3 pcs M6 nuts 8 Step 6 Open the door Put cylinder into the big hole on bottom panel and lock the cylinder chain Step 6 Tighten ...

Page 11: ...e solution by mixing 1part liquid dish soap and 3 parts water 2 Spoon or brush several drops or use squirt bottle of the solution onto hose connection regulator cylinder connection 3 Turn on gas cylinder valve Inspect the connections and look for bubbles 4 If no bubbles appear the connection is safe 5 If bubbles appear there is a leak Loosen and re tighten this connection If there is still a leak ...

Page 12: ...ove igniter button by turning counter clockwise Install AAA battery with positive terminal up as indicated in diagram Replace igniter button IGNITER BATTERY INSTALLATION Ignition button Control knob AAA battery Ignition button Replace Battery ...

Page 13: ...r lighting operations will cause serious injury and explosion Your heater was designed and approved for OUTDOOR USE ONLY DO NOT use it inside a building or any other enclosed area Make sure surrounding areas are free of combustible materials gasoline and other flammable vapors or liquids Ensure that there is no obstruction to air ventilation Be sure all gas connections are tight and there are no l...

Page 14: ...e pilot lights 4 Once the pilot is lit release the igniter button and continue to depress the control knob for 30 seconds 5 After depressing the control knob for 30 seconds release the control knob and turn it counter clockwise to the LOW or HIGH position Note If the pilot light will not ignite turn the control knob to the off position and fully close the propane tank valve Wait 5 minutes and then...

Page 15: ...t five 5 minutes before attempting to relight pilot 3 Repeat steps beginning with step 2 of the lighting instruction above Shut down instructions 1 Push in and turn control knob clockwise to OFF position 2 Turn LP cylinder gas valve clockwise to OFF position when heater is not in use Note After use some discoloration of the emitter screen is normal The Event of Gas Leakage 1 Turn the control knob ...

Page 16: ...er is primarily used for the heating of outdoor patios decks spas pools and open working areas Always make sure that adequate fresh air ventilation is provided Follow the spacing tolerances shown in Figure 1 at all times This heater must be placed on level firm ground Never operate in an explosive atmosphere Keep away from areas where gasoline or other flammable liquids or vapors are stored or use...

Page 17: ...and pilot assembly dry at all times If the gas control is exposed to water in any way do NOT try to use it It must be replaced Keep the appliance area free and clean from combustible materials gasoline and other flammable vapors and liquids not obstructing the flow of combustion and ventilation air keeping the ventilation opening s of the cylinder enclosure free and clear from debris Gas odor with...

Page 18: ... heavy duty pipe cleaner Compressed air may help clear away smaller particles Carbon deposits may create a fire hazard Clean dome and engine with warm soapy water if any carbon deposits develop STORAGE Between uses During periods of extended inactivity or when transporting Turn the control knob to OFF position Disconnect the regulator from the LP Cylinder by turning counter clockwise and move to a...

Page 19: ...ot will not stay on Debris around pilot Clean dirty area Tighten connection Thermocouple Contact customer service Gas leak in line Check connections Lack of fuel pressure Fuel tank is near empty Pressure is low Fuel tank is near empty Control valve not ON Turn valve to ON Thermocouple broken Contact customer service Contact customer service Pilot light assembly bent or not in correct location Burn...

Page 20: ...l consumer purchaser only and excludes industrial commercial or business use of the product product damage due to shipment or failure which results from alteration product abuse or product misuse whether performed by a contractor service company or consumer We will not be responsible for labor charges and or damage incurred in installation repair or replace ment nor for incidental or consequential...

Page 21: ...For sales inquiries contact Sylvane at 1 800 934 9194 If you have service questions contact Lava Heat at 1 888 779 5282 ...

Reviews: