4 Troubleshooting 

Symptoms Reasons 

Solutions 

The motor does not 
work. 

Thermo relay or circuit breaker actuated 
Voltage is not correct. 
Electrical wiring is wrong. 
Motor is broken. 

Reset the thermo relay or circuit breaker 
Supply power of correct voltage. 
Fix the wiring. 
Change motor. 

The motor works, but 
the platforms do not 
move, or can only go 
up slowly. 

The motor rotates in the wrong direction. 
 
Oil level is too low. 
Height limit switch is stuck or damaged. 

Exchange wiring of motor to change direction. 
Add oil. 
Repair or replace the height limit switch. 

The motor works, but 
the platforms can not 
lift the vehicle. 

The voltage to the motor is too low. 
Pressure of relief valve is not right. 
The lift is overloaded 
The hydraulic pump is damaged. 

Supply motor with correct voltage. 
Adjust the pressure of relief valve. 
Check the weight of the vehicle. 
Replace the hydraulic pump. 

The lift is too slow in 
lowering. 

There is foreign substance in the lowering 
solenoid valve. 
Lowering speed valve is turned too low. 

Clean the lowering solenoid valve. 
 
Turn the lowering speed valve up. 

The platforms are not 
synchronized. 

There is air in upper chamber of Master 
Cylinder or Slave Cylinder. 
 
 
The oil supply can not be cut off because of 
the leakage of stop valve. 
Leakage in hydraulic system 

Air bleeding performance is needed.    The air 
in the master and slave cylinder can be bled 
after the platform goes up and down several 
times

Replace stop valve. 
 
Replace the seal or the cylinder. 

Safety ratchets 
cannot be separated 
from serration. 

The air pressure regulating valve is closed 
or too low. 
The Solenoid air valve is damaged. 
The LOCK button is pressed for too long 
time. 

Adjust air pressure to 5kg/cm

 
Replace the solenoid air valve. 
Release the LOCK button immediately after 
the safety ratchets are fully engaged. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

Summary of Contents for TLT830WA

Page 1: ...entioned in this manual is to describe how to use this equipment Their registered trademarks still belong to the original companies This equipment is for the use of professional technical personnel or...

Page 2: ...the lift should be carried out regularly Do not operate a damaged lift or a lift with broken parts All the parts are only replaceable with the parts provided by the manufacturer z Do not overload the...

Page 3: ...lectrical Diagram 6 2 3 Hydraulic Diagram 6 2 4 Pneumatic Diagram 7 3 Operating Instruction 7 3 1 Operational Panel 7 3 2 Check before Working 8 3 3 Operating Procedure 8 3 4 Cautions for Operation 8...

Page 4: ...pneumatic control can help the operation easy safe and reliable z Height limit switch can prevent the machine from damage z All the moving parts use the maintain free bearings to guarantee the long t...

Page 5: ...ve on Ramp 340mm 1900mm 13 4 74 8 Control Desk 550mm 21 7 880mm 34 6 Big Scissor Cylinder Safety Ratchet 280mm 11 1400mm 55 1 4000mm 157 5 340mm 450mm 13 4 17 7 Small Scissor Cylinder Small Scissors P...

Page 6: ...ntrol 10 Solenoid Valve Manual Control 6 Relief Valve 7 Check Valve 8 Lowering Solenoid Valve Manual Control 9 Lowering Speed Control Valve 12 High Pressure Stop Valve 5 Motor 17 Small Scissor Slave C...

Page 7: ...LAUNCH TLT830WA USER S MANUAL 2 4 Pneumatic Diagram 7 Fig 4 3 Operating Instruction 3 1 Operational Panel Fig 5...

Page 8: ...lift is normal z Keep pressing the UP button and raise the vehicle to a proper height z Press the SAFETY LOCK button to lower the platforms The safety ratchets of both sides will be engaged to ensure...

Page 9: ...he pressure of relief valve Check the weight of the vehicle Replace the hydraulic pump The lift is too slow in lowering There is foreign substance in the lowering solenoid valve Lowering speed valve i...

Page 10: ...slide is well lubricated with high quality 2 lithium lubricant z Apply 2 lithium lubricant on a monthly basis 5 3 Every Six Month z Check all the moving parts for possible wearing interference and dam...

Page 11: ...rity microscopic method piece cm Above 10 m not more than Above 25 m not more than Above 75 m not more than Above 125 m not more than 5000 3000 500 0 Resembling viscosity 15 10s 1 Pa s not more than 8...

Page 12: ...cylinder 1 8 GB10708 1 89 Shaft sealing ring GY45x55x7 Big scissor master cylinder 1 9 GB1235 76 O ring 90x3 1 Small scissor master cylinder 2 10 GB1235 76 O ring 75x5 7 Small scissor slave cylinder 1...

Reviews: