Proline Edition X cooling thermostats
YACE0100 / October 4, 2018
35
7.5
"Master" menu structure
2 dots in the display, e.g.
MNEmv
, indicate
that a submenu follows.
3 dots in the display, e.g.
MNpfv
, indicate
that a module submenu follows.
2%32
Actual bath temperature
or actual value of
external temperature
SEt
Set setpoint
Section 7.7.1
Pu
Pump power
Section 7.7.3
Con
Control Int/Ext
Section 7.7.4
MNEmv
Settings
MNpfv
Conf. Modules
SEC
Protection system
C0MN
Command
C00l
Cooling system
AnA
Analog module
Section 8.4
rS
Conf. RS-232/485
Section 8.3
d1b
Conf. digit. mod.
PArB.
Parameters
P1d..
Control par.
Only internal or external
parameters are offered
depending on control
variable
ShoZ\
Show values
CAL..
Pt100 calibration
CAL 1
Offset int. Pt100
Section 7.8.7
dEF !
Works settgs. int. Pt
Section 7.8.8
CAL E
Offset ext. Pt100
Section 7.8.9
dEF E
Works settgs. ext. Pt
Section 7.8.10
UEr
Software version
Section 9.2.2
Snr_H
Serial number Hi Word.
Section 9.2.3
Snr_L
Serial number Lo Word.
Section 9.2.3
StELL
Control value of tempera.
controller. Section 9.2.4
tHEAd
Temp. of housing °C
Section 9.2.4
tHS
Temp. of heatsink °C
Section 9.2.4
FAn U
Fan voltage in V.
Section 9.2.4
1EFF
Mains curr. consumpt. in A
Section 9.2.4
U_SEC
Prot. syst. voltage in V.
Section 9.2.4
U24
Act. val. 24V voltage in V.
Section 9.2.4
PU 1
Current consumpt. pump I.
Section 9.2.4
PU P
Power consumpt. pump W
Section 9.2.4
PU n
Pump speed rpm.
Section 9.2.4
nF 50
Mains frequency Hz
Section 9.2.4
nU
Mains volt. % of rated volt.
Section 9.2.4
LE
Bath level [cm]
Section 9.2.4
tE Pt
Extern temp. Pt100
Section 9.2.4
tEAnA
Ext. temp. analog. interf.
Section 9.2.4
tESEr
Ext.temp. RS232/485
Section 9.2.4
iSEt
Curr. controller setpoint.
Section 9.2.4
SEtq.
Setpoint relat. to act.
val. Section 7.8.4
S
Setpoint resolution
Section 7.8.1
StArt
Opern. w. mains fail.
Section 7.8.2
tih
Upper temp. limit
Section 7.8.3
Cur
Max. current consumpt.
Section 7.7.5
tiL
Lower temp. limit
Section 7.8.3
tYPG.
Detect type of unit.
Section 9.2.1
dEF
Works setting
Section 7.8.5
Audjp
Signal settings.
Section 7.8.6
H_All
Counter operating hours
Master complete
H_PU
Counter operating hours
Pump
td
Int. damping time (Td)
Section 7.13.1
_P
Int. proport.range (Xp)
Section 7.13.1
tn
Internal reset time (Tn)
Section 7.13.1
tu
Int. derivative time (Tv)
Section 7.13.1
tud
Int. contr. par. auto/man.
Section 7.13.1
dEF
Works settings
Section 7.13.1
iP
External P-controller (Xpf)
Section 7.13.2
Ev
Ext. derivative time (Tve)
Section 7.13.2
Ed
Ext. damping time (Tde)
Section 7.13.2
Eb
Ext.propor.range (Prop_E)
Section 7.13.2
Et0L
Ext.correct. var. (K)
Section 7.13.2
E
Ext. contr.par. auto/ man.
Section 7.13.2
dEF
Works settings
Section 7.13.2
En
External reset time (Tne)
Section 7.13.2
EP
Ext. prop. factor (Kpe)
Section 7.13.2
Summary of Contents for Proline RP 1290 C
Page 2: ......
Page 4: ......
Page 115: ...Proline Edition X cooling thermostats YACE0100 October 4 2018 115 Blank page ...
Page 116: ...Proline Edition X cooling thermostats 116 YACE0100 October 4 2018 Blank page ...
Page 118: ......
Page 119: ......