background image

Platform Manager

Development Kit

Run the Platform Manager Demo

Initial board setup:

•  Set all DIP switches in SW9 and SW10 to the up/off position.

•  Set all DIP switches in SW2 to the on position.

•  Set slide potentiometers (pots) R19 and R20 to the down position, toward the 

center of the board.

•  No jumpers should be installed.

Demo 1 – Test Board Power, LED D1, and All Power Supplies

Demo 1 shows the ability of the Platform Manager to monitor and sequence input power 

rails and on-board supplies. There are five supplies connected to five seperate VMON 

inputs on the Platform Manager Evaluation Board. The first three supplies, 5V, 3.3V, 

and 2.5V, are power rails that the Platform Manager does not enable; it is only monitors 

them. The second 2.5V supply is an LDO that the Platform Manager enables and then 

monitors, and the 1.2V supply is a DC-DC converter that the Platform Manager enables 

and then monitors. There is also control from the Margin/Trim outputs on the Platform 

Manager to each of these supplies. The table below shows how the four LEDs in the 

display follow the progress of the monitoring, enabling, and sequencing.

•  Plug the 5V wall plug supply into the board supply plug.

 

- The blue LED D1 is on and will remain on while the board is powered.

 

- LEDs D21-D23 cycle through steps 1-6 as shown in the table below. Failure to 

 

  cycle through the steps indicates a power supply error.

Step D24 D23 D22 D21

Function

1

Off

Off

Off

ON

 Wait for 5V supply good

2

Off

Off

ON

Off  Wait for 3.3V supply good

3

Off

Off

ON

ON

 Wait for 2.5V supply good

4

Off

ON

Off

Off  Enable 2.5V LDO, wait for 2.5V good 

5

Off

ON

Off

ON

 Enable 1.2V DC-DC, wait for 1.2V good

6

Off

ON

ON

Off  Waiting for Slide Pots R19 and R20 to be raised to the top of the Slide

Demo 2 – Test Slide Pots R19-R20 and LEDs D3-D6, D13-D14, D19-D20 and 

D21-D24 

Demo 2 tests the position of the slide pots, and displays patterns and information on 

the LEDs and LCD display. The slide pots are connected to two VMON inputs of the 

Platform Manager and are set to be “good” at about 3V. The demo checks for both pots 

to be at good levels, then continues to the next step, which is to exercise various digital 

outputs from the Platform Manager. Platform Manager outputs connect to the LEDs, as 

shown in the tables below, and also to the LCD. The Closed Loop Trimming function for 

the LDO and DC-DC converter is also enabled at this point.