20
Ensure that there are no air gaps during application of the cement/mortar cement based adhesive/tile adhesive/thinset or self-leveling
compound.
Ensure the entire STRATA_HEAT™ Wire, factory splices and STRATA_HEAT Thermostat floor sensor are embedded in the cement mortar.
The choice and application of building materials should be in accordance with building materials manufacturer’s instructions.
Ensure that the correct maturity and curing times for drying of construction materials is followed before you powering ON the
STRATA_HEAT Wire.
Test the heaters before, during and after installation of the final floor finish. Record values in the control card on page 23
of this
manual.
Operating Tips
When first energized, the under tile STRATA_HEAT Wire may take up to 3 hours to fully warm your floor.
Energy consumption will vary depending on user preferences. For lower energy consumption set the STRATA_HEAT Thermostat to
optimum temperature setting.
Energy consumption can be minimized by turning the system OFF when floor heat is not required, but you will have to allow time for the
floor to warm up once the system is turned ‘ON’ again.
We recommend and supply STRATA_HEAT Thermostats with “set-back” option. This option will reduce the heat-up time to less than 1
hour by reducing the floor temperature and not actually turning off the system during the setback period(s).
Avoid placing thick mats / rugs / floor level furniture / mattresses on your heated floor, specially in the area where the sensor of a floor-
sensing thermostat is located. These restrict the transfer of heat away from the STRATA_HEAT Wire and result in the floor area beneath
them being warmer than other areas.
Avoid mats with rubber or vinyl type backing, as these may decompose with heat and could stain flooring.