background image

2000 – 4000 Series Time Recorder User’s Guide

 

 

Page 

4

 

 

If your model prints Tenths, (models with the 4

th

 digit of 2 or 5), go to 

the section “

Setting Decimal Wheel with Tenths

”. 

If your model prints Hundredths or 00-23 hours, refer to the 

Dial of 

Decimal Equivalents in Figure 3

 (page 6) to determine the correct 

setting. 

Note: if your machine records in 1-12 hours, the PM hours are 
underlined. AM hours are not underlined.  Set time to the proper hour 
of the day to avoid errors such as setting the day wheel to the next 
day at noon rather than midnight. 

3.

 

Rotate the Minute Wheels to show the current minute. 

4.

 

Set the Hour Wheel to the current hour 

5.

 

Rotate the 

Clock Face

 

Setting Wheel – Figure 5.1 on page 8,

 

to set the hands to match the time set on the wheels. 

6.

 

Rotate the 

Main Setting Wheel – Figure 2, 2.1

 to advance both 

the Clock Face and Print Wheels together.  Rotate until you 
pass the actual time by one minute (each “click” indicates one 
minute.) 

7.

 

Hold the corner of the Clock Face and release the 

Release 

Latch – Figure 2, 2.2

 by pushing it to the left.  Slowly let the 

Type Section down and press it firmly into the Type Section 
Headlock. 

8.

 

Make a sample registration and verify the time and date or day 
is correct. 

9.

 

Replace and lock the case cover. 

Note:  The month wheel and the date wheel must be reset manually at 

the beginning of each month. 

2000 – 4000 Series Time Recorder User’s Guide

 

Page 9 

Changing the Ribbon 

 

Lathem time recorders have self-reversing ribbons.  With normal use, a 
ribbon should last for many months or even years….and when the time 

comes, it is easy to change. 

 

Figure 7 

1.

 

Remove the top cover and raise type section (see “Raise the 
type section” on page 4.) 

2.

 

Remove the 

cotter pins – Figure 7, 7.1

 that retain the ribbon 

spools and slide off old spools. 

3.

 

Lift 

ribbon hold-down guide – Figure 7, 7.2

 – use a pencil to 

support it in an up position. 

4.

 

Remove ribbon and replace with new Lathem ribbon.  Make 

sure the ribbon feeds from bottom of the spools and runs 
BETWEEN 

reversing fingers – Figure 7, 7.3

, the red side should 

be aligned with the date or day wheel(s). 

5.

 

Install cotter pins; remove pencil, and lower the type section 

into place. 

 

Summary of Contents for 2000 - 4000 Series

Page 1: ...Printed in USA P N OMOV0605A r 2000 4000 Series User s Guide...

Page 2: ...shall be limited to repair of this product or replacement thereof at the sole discretion of Lathem 5 If it becomes necessary to send the product or any defective part to Lathem or any authorized serv...

Page 3: ...ach Screw 10 2 one quarter of a turn clockwise 10 Plug cord back in wall outlet and reset the time 2000 4000 Series Time Recorder User s Guide Page 1 Ordering Accessories Lathem time recorders fulfill...

Page 4: ...corder User s Guide Page 11 Install Replace Batteries in BATT Figure 9 The 2000 BATT requires four D size batteries and should operate for six months before replacement An internal beeper sounds momen...

Page 5: ...to remove it 2 Note the position of the Release Latch and Face Setting Wheel used later in this process 3 Wait until you hear the clock click 4 Press either side of the Type Section Headlock Figure 1...

Page 6: ...ck Face and release the Release Latch Figure 2 2 2 by pushing it to the left Slowly let the Type Section down and press it firmly into the Type Section Headlock 8 Make a sample registration and verify...

Page 7: ...inute button to advance to the next minute Seconds are now synchronized Always set the display to regular minutes Refer to Figure 3 dial of decimal equivalent if wheels print in hundredths or tenths 2...

Page 8: ...one minute each click indicates one minute For example at 10 05 rotate 5 times 5 clicks 5 minutes past ten o clock 5 Hold the corner of the Clock Face and release the Release Latch by pushing it to t...

Reviews: