![lassele LUI-150A Installation And User Manual Download Page 8](http://html1.mh-extra.com/html/lassele/lui-150a/lui-150a_installation-and-user-manual_3797131008.webp)
8
9
Please read the following cautions;
- The Icemaker must have the earthwork done.
- The Icemaker must have exchangeable fuse or circuit breaker.
- Decide the appropriate size of the wire based on the length, thickness, and position of the wires.
- Above work has to be done by a qualified electrical engineer.
2.3 Electrical Requirements
WARNING
- All kinds of power wiring work including power cable connection and earth have to be done
in accordance to the law and regulations of the country, state, and region.
- The earthwork for icemaker has to be done in accordance to the law and regulations of the
country, state, and region.
●
Voltage
- When operating the icemaker (with maximized electrical load) range of variation in maximum
voltage allowed is ±10% of the rate voltage.
●
Fuse/Circuit Breaker
- Must have the exclusive fuse/circuit breaker for the ice maker.
- Must use a circuit breaker in accordance with applicable national, state and local regulations.
Condition
Minimum
Maximum
Ambient Temperature
°F
45
100
°C
7
38
Water Temperature
°F
45
90
°C
7
32
Water Pressure
psig
30
100
kPa
206.8
689.4
Voltage
115V
100
130
220V
208
230
●
Installation condition